Skip to main content

Impact of prosthesis–patient mismatch on short-term outcomes after aortic valve replacement: a retrospective analysis in East China

Abstract

Background

Prosthesis–patient mismatch (PPM) may affect the clinical outcomes of patients undergoing aortic valve replacement (AVR). We aimed to determine the incidence of PPM, its effect on short-term mortality, and the factors contributing to PPM in China.

Methods

We retrospectively examined all consecutive patients with isolated or concomitant AVR at our hospital between January 1, 2013 and December 31, 2015. PPM was defined as an effective orifice area index (EOAi) of ≤ 0.85 cm2/m2. The baseline, echocardiographic, operative, and outcome data of all patients were collected from the national database.

Results

A total of 869 patients were included in the study. PPM was detected in 15.9% (138/869) of the patients. Four patients (0.5%) met the criteria for severe PPM. Patients with PPM were older and had a higher prevalence of diabetes, coronary heart disease, aortic stenosis (AS), and preoperative left ventricular dysfunction but a lower incidence of smoking history and aortic regurgitation. Logistic regression analysis showed that female gender (P < 0.001), AS (P = 0.014), higher body mass index (BMI) (P < 0.001), and bioprosthesis (P < 0.001) were independent predictors of PPM. We also found that PPM (P = 0.005) was associated with 30-day all-cause mortality, along with smoking history (P = 0.001) and low preoperative left ventricular ejection fraction (LVEF) (P = 0.004).

Conclusions

PPM is associated with high short-term mortality after AVR in China. Female gender, aortic stenosis, bioprosthesis, and high BMI are risk factors for the incidence of PPM.

Peer Review reports

Background

Prosthesis–patient mismatch (PPM) after aortic valve replacement (AVR) surgery was first mentioned in 1978 by Rahimtoola, and has been a topic of discussion ever since [1]. PPM occurs when the effective orifice area (EOA) of the implanted prosthesis is too small in relation to the patient’s body size.

The clinical significance of PPM after AVR remains controversial even after 37 years since its first description. Some studies have showed favorable results despite the occurrence of PPM after AVR [2,3,4], while several other clinical studies have demonstrated that aortic PPM might be associated with an increased incidence of long- and short-term adverse outcomes, including cardiac-related death [5, 6]. Patients with valvular diseases in East China have smaller body surface area, more rheumatic causes and lower anticoagulation intensity requirements [7]. Therefore the incidence, predictions and complications of PPM in East China patients might differ greatly from patients in the western countries. However, study regarding PPM in this specific group of patients has seldom been reported.

For these reasons, we retrospectively analyzed PPM in patients undergoing first time isolated or concomitant AVR in East China and aimed to determine the incidence of PPM, its effect on short-term mortality, and the factors contributing to PPM.

Methods

Patient population and data collection

This study was conducted at a single large cardiothoracic surgical center in southeast China. After obtaining written informed consent waived by the Hospital Review Board, we reviewed data from the Chinese Adult Cardiovascular Surgery Database, which holds clinical information on all patients at the center, the Department of Cardiothoracic Surgery at the First Affiliated Hospital, Zhejiang University, China, since April 2013.

We analyzed all consecutive patients aged > 18 years undergoing first time isolated or concomitant AVR at the center from January 1st, 2013 to December 31st, 2015. Patients requiring a composite valve vascular prosthesis procedure were excluded.

In total, 869 patients were included in this study. Baseline, operative, and outcome data of the patients were prospectively collected, validated, and entered into the database, which was queried retrospectively. A 30-day postoperative follow-up was conducted for all discharged patients at the outpatient clinic.

PPM and definitions

Body surface area (BSA) was derived from the Dubois formula. The aortic valve prosthesis effective valve orifice area (EOA) was derived from in vitro measurements provided by the manufacturers and from scientific publications, as outlined in Table 1.

Table 1 In vivo effective orifice area values (cm2) corresponding to each valve

EOA was divided by BSA to obtain the effective orifice area index (EOAi). PPM was defined as EOAi ≤ 0.85 cm2/m2 [8]. EOAi ≤ 0.65 cm2/m2 was considered severe PPM.

Chronic renal insufficiency: serum creatinine ≥ 2 mg/dl. Peripheral arterial disease: claudication, carotid stenosis > 50% or previous/planned intervention on the abdominal aorta, limb arteries or carotids. Coronary artery disease: ≥ 50% reduction in one or more coronary vessels in single or more plane angiographic images. Emergency surgery: operation required within 24 h of onset of symptoms. Postoperative renal failure: the increase in baseline creatinine greater than 2 mg/dl.

Surgical technique

The surgical records of all patients were reviewed. A total of 210 aortic valve bioprostheses and 659 aortic valve mechanical prostheses were implanted. The prostheses used included: Hancock II Procine Bioprosthesis (120 patients) and Mosaic Procine Bioprosthetic Valves (four patients) (Medtronic, Inc, Minneapolis, Minn), Biocor Stented Tissue Valve (47 patients) (St Jude Medical, Inc, St Paul, Minn), Carpentier-Edwards Perimount (32 patients) and Carpentier-Edwards Perimount Magna Ease (seven patients) (Baxter Healthcare Corp, Edwards Division, Santa Ana, Calif), CarboMedics Orbis Universal Valve (517 patients) (CarboMedics, Inc, Austin, TX), ATS Open Pivot 500FA, 500DM (ten patients) and ATS Open Pivot AP360 (two patients) (ATS Medical, Inc, Minneapolis, Minn), St Jude Regent Valve (40 patients) and St Jude Master Series Heart Valves (90 patients) (St Jude Medical, Inc, St Paul, Minn) (Table 1).

An isolated or concomitant aortic valve replacement was performed in all patients. Concomitant operations in some of the patients included coronary artery bypass grafting and other heart valve procedures. Standard anesthesia and surgical technique, extracorporeal circulation and myocardial protection methods were used. Most of the patients were approached through a full median sternotomy followed by antegrade 4:1 cold blood cardioplegia for myocardial protection. Antegrade plus retrograde cardioplegia was applied for patientis with coronary stenosis. Intermittent perfusion of cold blood cardioplegia was maintained, with a frequency of once every 20 min.

After consulting the patients and their relatives preoperatively, a decision on the type of prosthesis was made by the surgeon, taking into consideration the preoperative characteristics and the intraoperative findings. The largest suitable prosthesis was chosen. When performing the valve replacement procedure, we applied simple interrupted mattress suturing with pledget on the left ventricular side of the annulus to ensure a larger orifice area and a shorter cross-clamp time.

Statistical analysis

The Kolmogorov-Smirnov test and/or Shapiro-Wilk test was used to verify the normality of the quantitative variables as appropriate. Continuous variables were presented as mean ± standard deviation, whether Gaussian distributed or median (interquartile range). Categorical variables were expressed as an absolute number (percentage). Pearson’s χ2 test was used for descriptive, univariate statistics, such as the comparison of portions, while Student’s unpaired T-test was used for normally distributed data comparisons. The Mann-Whitney U test was used for group comparison of continuous non-Gaussian distributed variables. Two-tailed P-values were derived from the calculated test statistics, and P ≤ 0.05 was considered statistically significant. Binary multivariate logistic regression analysis by the forward method was performed to study the factors affecting PPM and mortality. SPSS software for windows (version 19.0) was used to analyze the data.

Results

Patient characteristics and preoperative data

A total of 869 consecutive patients were included in the study. PPM was detected in 15.9% (138/869) of the patients. Four patients (0.5%) met the criteria for severe PPM. Smaller valve sizes are related to higher rate of PPM (Table 1). Compared with the non-PPM group, patients with PPM were older and had a higher prevalence of diabetes, coronary heart disease, AS, and preoperative left ventricular ejection fraction (LVEF). But the incidence of smoking history and aortic regurgitation was relatively low in PPM patients (Table 2).

Table 2 Preoperative patient characteristics

Operative data

As shown in Table 3, there were no significant differences between the groups regarding cardiopulmonary bypass (CPB) time, aortic cross-clamp time, and mitral valve procedure combined. However, remarkably more patients with prosthesis–patient mismatch were implanted with a bioprosthetic aortic valve.

Table 3 Characteristics of the surgical procedure

Factors affecting prosthesis-patient mismatch

According to a multivariate logistic regression analysis including all preoperative and intraoperative variables, patients with PPM had a higher incidence of female gender (P < 0.001; OR = 0.307; 95% CI, 0.19–0.486), a higher incidence of AS (P = 0.014; OR = 1.725; 95% CI, 1.118–2.663), higher body mass index (BMI) (P < 0.001; OR = 1.092; 95% CI, 1.029–1.160), and more frequently received a bioprosthesis (P < 0.001; OR = 13.907; 95% CI, 8.703–22.222) than those without a mismatch (Table 4).

Table 4 Logistic regression model for prosthesis-patient mismatch

Major postoperative complications

There were no significant differences between the two groups regarding most of the postoperative patient data and complications, including perioperative blood transfusion, ventilation time, reintubation, duration of first time in ICU, reentering ICU, chest tube output, reoperation, sternal wound infection, postop stroke, postop renal failure, persistent atrial fibrillation (AF), multi organ failure, and length of hospital stay (p > 0.05). However, all-cause postoperative 30-day mortality was higher in the PPM group than in the non-PPM group (2.1% vs 0.5%, p = 0.050).

Factors affecting postoperative mortality

Seven patients (0.8%) died during the postoperative hospitalization period, three (2.1%) with and four (0.5%) without PPM (p = 0.050). Five deaths were cardiac related; the other two patients (both without PPM) died due to severe infection. No patient died intraoperatively or within 30 days post discharge.

A binary multivariate logistic regression model was constructed to analyze factors relating to all-cause death (Table 5). The results of the analysis showed that patients with a smoking history (P = 0.001; OR = 44.780; 95% CI, 4.303–466.014) and a lower preoperative left ventricular ejection fraction (LVEF) (P = 0.004; OR = 0.884; 95% CI, 0.813–0.961) had a higher incidence of postoperative death. More strikingly, prosthesis–patient mismatch was found to be associated with global or cardiac early mortality (P = 0.005; OR = 16.493; 95% CI, 2.306–117.950).

Table 5 Logistic regression model for postoperative 30-day global mortality

Discussion

Based on the aforementioned definitions, the incidence of PPM in our single-centered cohort was 15.9%, and only 0.5% of the cases met the criteria for severe PPM. Although highly variable, PPM rates in most of the literature were higher than 20% [8]. The low rate of PPM in this study might be related to the particular physical condition of East Asians. First, East Asian population has considerably smaller body surface area than western populations. Also, the patients in this district are generally younger due to higher incidence of rheumatic causes, demanding more mechanical prosthesis, which may explain the lower incidence of PPM. A similar low rate of PPM has been reported by Japanese and Indian scientists [9, 10].

Predictors of PPM

We performed logistic regression analysis and found AS to be an independent risk factor for PPM. The reason why PPM occurs more frequently in patients with AS than aortic regurgitation is that patients with a stenotic native aortic valve tend to have smaller valvular annuli. It is also one of the reasons why older people, observed more frequently with calcified AS, had a higher incidence of mismatch. Another reason is that older patients, especially those aged over 65, were implanted with a bioprosthetic valve. Mechanical valves, compared to stented bioprostheses, have a more favorable relationship between the external diameter and the EOA [11], thus reducing the incidence of PPM. Diabetes and atherosclerosis may also be related to AS and old age, indirectly influencing the rate of PPM.

We also found that there were more female patients in the PPM group (59% female and 41% male), consistent with other studies [12]. The study showed that women had smaller aortic root diameters than men [13], making them more likely to be implanted with a small sized valve prosthesis. This may explain why there were more smokers in the non-PPM group of our study. Our study also showed that PPM was associated with higher BMI. Therefore, weight control should be urged in obese patients to minimize the adverse effects of PPM.

Effect of PPM on early mortality

There were no obvious differences regarding early postoperative patient data and complications between the two groups. However, logistic regression analysis showed that PPM was an independent factor predicting postoperative 30-day all-cause mortality, along with smoking history and low preoperative LVEF. The high mortality may be associated with the increased hemodynamic burden imposed by PPM. Further, the combination of poor ventricular function and moderate to severe PPM may dramatically increase mortality risk [14].

Clinical implication and prevention

Some studies have shown that PPM affects long- and short-term postoperative morbidity and mortality [14, 15], whereas other studies have proven that even severe PPM does not increase the incidence of adverse outcomes [4, 16].

Aortic root enlargement surgery is an alternative procedure to avoid PPM. However, preventative root enlargement surgery may be related to prolonged off-pump time and increased risk [17, 18]. Therefore, considering the relatively low rate of PPM in China, we did not take aggressive root enlargement as a routine procedure in patients with a risk of mismatch. However, the implantation of newer-generation biological or mechanical prostheses with or without aortic annular enlargement should be considered according to the characteristics of the patient and the risk-benefit ratio for carrying out a particular procedure in an individual patient.

Out data have shown that although PPM does not affect the incidence of postoperative complications, all-cause early mortality of the patients did increase. Therefore, a randomized controlled trial will be carried out next to evaluate the effect of root enlargement strategies in selected young patients.

The results of this retrospective study have updated our understanding of PPM and encourage a positive view of preventative root enlargement strategies in patients with PPM.

Limitations of the study

This was a retrospective study; the analysis, therefore, has inherent disadvantages. The recorded differences in patient outcomes could originate from smaller recorded or unrecorded differences between the two groups.

EOA was predicted by reference tables, which may not reflect the actual in vivo values of the EOAi. The effect of PPM on long-term outcomes and survival was not studied. Moreover, this was a single-centered analysis, thus the extrapolation of the results should be treated cautiously. However the sample size is acceptable. Comparing to a multi-centered study, our single-center analysis have the advantage of minimizing the deviation in patient surgical outcomes caused by uneven surgical procedures, varied skills of surgeons and different myocardial protection strategies.

Nevertheless, a randomized prospective multi-centered clinical trial is needed for further evaluation of the effect of PPM on longer term hemodynamic function, left ventricular function, and overall patient outcomes.

Conclusions

This study demonstrates that female gender, aortic stenosis, bioprosthesis, and high BMI are risk factors for PPM in patients undergoing AVR. PPM is associated with a higher short-term mortality after AVR in China.

Abbreviations

AF:

Atrial fibrillation

AS:

Aortic stenosis

AVR:

Aortic valve replacement

BMI:

Body mass index

BSA:

Body surface are

CABG:

Coronary artery bypass grafting

CI:

Confidence interval

CPB:

Cardiopulmonary bypass

EOA:

Effective orifice area

EOAi:

Effective orifice area index

ICU:

Intensive care unit

LVEF:

Left ventricular ejection fracture

NYHA:

New York Heart Association

OR:

Odd ratio

PPM:

Prosthesis-patient mismatch

References

  1. Rahimtoola SH. The problem of valve prosthesis-patient mismatch. Circulation. 1978;58(1):20–4.

    Article  CAS  PubMed  Google Scholar 

  2. Howell NJ, Keogh BE, Ray D, et al. Patient-prosthesis mismatch in patients with aortic stenosis undergoing isolated aortic valve replacement does not affect survival. Ann Thorac Surg. 2010;89(1):60–4.

    Article  PubMed  Google Scholar 

  3. Howell NJ, Keogh BE, Barnet V, et al. Patient-prosthesis mismatch does not affect survival following aortic valve replacement. Eur J Cardiothorac Surg. 2006;30(1):10–4.

    Article  PubMed  Google Scholar 

  4. Sportelli E, Regesta T, Salsano A, et al. Does patient-prosthesis mismatch after aortic valve replacement affect survival and quality of life in elderly patients? J Cardiovasc Med. 2016;17(2):137–43.

    Article  Google Scholar 

  5. Hong S, Yi GJ, Youn YN, Lee S, Yoo KJ, Chang BC. Effect of the prosthesis-patient mismatch on long-term clinical outcomes after isolated aortic valve replacement for aortic stenosis: A prospective observational study. J Thorac Cardiov Sur. 2013;146(5):1098–104.

    Article  Google Scholar 

  6. Fuster RG, Montero Argudo JA, Albarova OG, et al. Patient-prosthesis mismatch in aortic valve replacement: really tolerable? Eur J Cardiothorac Surg. 2005;27(3):441–9. discussion 9.

    Article  PubMed  Google Scholar 

  7. Zhou XM, Zhuang W, Hu JG, Li JM, Yu JF, Jiang L. Low-dose anticoagulation in Chinese patients with mechanical heart valves. Asian Cardiovasc Thorac Ann. 2005;13(4):341–4.

    Article  PubMed  Google Scholar 

  8. Pibarot P, Dumesnil JG. Prosthesis-patient mismatch: definition, clinical impact, and prevention. Heart. 2006;92(8):1022–9.

    Article  CAS  PubMed  Google Scholar 

  9. Kaminishi Y, Misawa Y, Kobayashi J, et al. Patient-prosthesis mismatch in patients with aortic valve replacement. Gen Thorac Cardiovasc Surg. 2013;61(5):274–9.

    Article  PubMed  PubMed Central  Google Scholar 

  10. Joshi SS, Ashwini T, George A, Jagadeesh AM. Patient prosthesis mismatch after aortic valve replacement: An Indian perspective. Ann Card Anaesth. 2016;19(1):84–8.

    Article  PubMed  PubMed Central  Google Scholar 

  11. Muneretto C, Bisleri G, Negri A, Manfredi J. The concept of patient-prosthesis mismatch. J Heart Valve Dis. 2004;13 Suppl 1:S59–62.

    PubMed  Google Scholar 

  12. Head SJ, Mokhles MM, Osnabrugge RL, et al. The impact of prosthesis-patient mismatch on long-term survival after aortic valve replacement: a systematic review and meta-analysis of 34 observational studies comprising 27 186 patients with 133 141 patient-years. Eur Heart J. 2012;33(12):1518–29.

    Article  PubMed  Google Scholar 

  13. Bonderman D, Graf A, Kammerlander AA, et al. Factors determining patient-prosthesis mismatch after aortic valve replacement--a prospective cohort study. PLoS One. 2013;8(12):e81940.

    Article  PubMed  PubMed Central  Google Scholar 

  14. Blais C, Dumesnil JG, Baillot R, Simard S, Doyle D, Pibarot P. Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replacement. Circulation. 2003;108(8):983–8.

    Article  PubMed  Google Scholar 

  15. Walther T, Rastan A, Falk V, et al. Patient prosthesis mismatch affects short- and long-term outcomes after aortic valve replacement. Eur J Cardiothorac Surg. 2006;30(1):15–9.

    Article  PubMed  Google Scholar 

  16. Hoffmann G, Ogbamicael SA, Jochens A, et al. Impact of patient-prosthesis mismatch following aortic valve replacement on short-term survival: a retrospective single center analysis of 632 consecutive patients with isolated stented biological aortic valve replacement. Thorac Cardiov Surg. 2014;62(6):469–74.

    Article  Google Scholar 

  17. Sommers KE, David TE. Aortic valve replacement with patch enlargement of the aortic annulus. Ann Thorac Surg. 1997;63(6):1608–12.

    Article  CAS  PubMed  Google Scholar 

  18. Carrier M, Pellerin M, Perrault LP, et al. Experience with the 19-mm Carpentier-Edwards pericardial bioprosthesis in the elderly. Ann Thorac Surg. 2001;71(5 Suppl):S249–52.

    Article  CAS  PubMed  Google Scholar 

  19. Pibarot P, Dumesnil JG. Hemodynamic and clinical impact of prosthesis-patient mismatch in the aortic valve position and its prevention. J Am Coll Cardiol. 2000;36(4):1131–41.

    Article  CAS  PubMed  Google Scholar 

  20. Sakamoto Y, Hashimoto K. Update on aortic valve prosthesis-patient mismatch in Japan. Gen Thorac Cardiovasc Surg. 2013;61(12):669–75.

    Article  PubMed  Google Scholar 

  21. Bach DS, Sakwa MP, Goldbach M, Petracek MR, Emery RW, Mohr FW. Hemodynamics and early clinical performance of the St. Jude Medical Regent mechanical aortic valve. Ann Thorac Surg. 2002;74(6):2003–9. discussion 9.

    Article  PubMed  Google Scholar 

  22. Tech Specs of Masters Series Mechanical Heart Valve. http://professional.sjm.com/. Available at: http://professional.sjm.com/products/sh/mechanical-valves/aortic-mitral/masters-series#tech-specs. Accessed 20 Mar 2016.

  23. Thomson DJ, Jamieson WR, Dumesnil JG, et al. Medtronic mosaic porcine bioprosthesis satisfactory early clinical performance. Ann Thorac Surg. 1998;66(6 Suppl):S122–5.

    Article  CAS  PubMed  Google Scholar 

  24. Pibarot P, Dumesnil JG. Prosthetic heart valves: selection of the optimal prosthesis and long-term management. Circulation. 2009;119(7):1034–48.

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

The authors would like to thank the anesthetists, intensivists, heart surgeons, nursing staff, perfusionists and the laboratory department at the First Affiliated Hospital, Zhejiang University for the collection and management of the data presented in this report. The authors also would like to thank Dr. Malik Akuffu Armah of Zhejiang University for language editing and proof reading of the manuscript.

Funding

Not applicable.

Availability of data and material

The datasets during and/or analysed during the current study available from the corresponding author on reasonable request.

Authors’ contributions

JZ and LC analyzed and interpreted the patient data, and wrote the paper. LM and RL prepared the tables and figure, and were major contributors in writing the manuscript. LG and HZ drafted the final manuscript. LG revised the manuscript. LG and JZ contributed equally to this study. All authors read and approved the final manuscript.

Competing interests

The authors declare that they have no competing interests.

Consent for publication

Not applicable.

Ethics approval and consent to participate

Written informed consent waived by the Hospital Review Board.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Haige Zhao.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Guo, L., Zheng, J., Chen, L. et al. Impact of prosthesis–patient mismatch on short-term outcomes after aortic valve replacement: a retrospective analysis in East China. J Cardiothorac Surg 12, 42 (2017). https://doi.org/10.1186/s13019-017-0596-2

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13019-017-0596-2

Keywords