Skip to main content

Table 5 Complications and resolution of symptoms in patients with benign diseases after covered and uncovered stent placement

From: An outcome analysis of self-expandable metallic stents in central airway obstruction: a cohort study

 

Total (n = 116)

Covered (n = 42)

Uncovered (n = 74)

p value¶

Complication rate

   Stent migration, n(%)

8(6.9)

4(9.5)

4(5.4)

0.458

   Granulation tissue formation, n(%)

22(19.0)

7 (16.7)

15(20.3)

0.634

   Stent fracture, n(%)

19(16.4)

5(11.9)

14(18.9)

0.44

Resolution of symptoms, n(%)

89(76.7)

30 (71.4)

59 (79.7)

0.363

  1. Abbreviations: p value, covered vs. uncovered stents; SEMS, self-expandable metallic stent