Skip to main content

Table 2 Operative and perfusion data

From: Safety and efficacy of biocompatible perfusion strategy in a contemporary series of patients undergoing coronary artery bypass grafting – a two-center study

Variable

Percent or mean, SD (Median, range) (n = 964)

Priority of surgery

 

 Elective

546 (56.6%)

 Urgent

348 (36.1%)

 Emergent

63 (6.5%)

 Emergent-salvage

7 (0.7%)

Redo surgery

14 (1.5%)

Number of vessels bypassed

2.7 ± 0.8 (3, 1–5)

Usage of arterial grafts

 

 Left internal mammary artery

938 (97%)

 Right internal mammary artery

267 (28%)

 Radial artery

125 (13%)

Cardiopulmonary bypass time (min)

95 ± 31 (93, 19–309)

Aortic cross-clamp time (min)

64 ± 21 (63, 12–169)

Lowest systemic temperature (°C)

35 ± 12 (35, 26–37)

Total heparin dose (mg/Kg)

1.9 ± 1.0 (1.7, 0.1-8.6)

Total protamine dose (mg/Kg)

1.0 ± 0.5 (0.9, 0–5.4)

Highest ACT during CPB (sec)

360 ± 326 (335, 130–999)

Lowest ACT during CPB (sec)

273 ± 42 (264, 139–524)