From: One-year patency control and risk analysis of eSVS®-mesh-supported coronary saphenous vein grafts
Graft | Distal Anastomosis | Number (n) | Mean Flow by TTFM (ml/min) | Pulsatility Index (TTFM) | Patent Grafts (n) | Occluded Grafts (n) |
---|---|---|---|---|---|---|
Left Coronary System | ||||||
LIMA | Single | 15 | 40 ± 32.4 | 2.0 ± 0.6 | 15 | 0 |
Jump | 21) | 39 ± 0.0 | 2.2 ± 0.8 | 2 | 0 | |
RIMA | Single | 2 | 58 ± 14.1 | 1.4 ± 0.6 | 2 | 0 |
Jump | 22) | 29 ± 8.5 | 1.3 ± 0.4 | 2 | 0 | |
RADIAL A. | Single | 1 | 19 | 1.2 | 1 | 0 |
SVG UNMESHED | Jump | 43) | 37 ± 21.1 | 2.4 ± 1.0 | 4 | 0 |
SVG MESHED | Jump | 104) | 73 ± 56.2 | 1.6 ± 0.4 | 9 | 1 |
TOTAL | 36 | 35 | 1 | |||
Right Coronary System | ||||||
SVG UNMESHED | Single | 2 | 67 ± 20.5 | 1.25 ± 0.7 | 2 | 0 |
Jump | 15) | 58 | 2 | 1 | 0 | |
SVG MESHED | Single | 10 | 41 ± 28.1 | 1.5 ± 0.8 | 6 | 4 |
Jump | 16) | 78 | 2 | 1 | 0 | |
Total | 14 | 10 | 4 |