Table 1 Hemodynamic data before and after acute heart failure

From: Comparison of effects of extra-thoracic paraaortic counterpulsation to intraaortic balloon pump on circulatory support in acute heart failure

  CO (L/min) PCWP (mmHg) MAP (mmHg) LVEDP (mmHg)
Normal 3.84 ± 0.21 6.50 ± 1.06 93.75 ± 4.06 -1.00 ± 1.69
HF 2.75 ± 0.19* 11.00 ± 1.31* 59.13 ± 5.54* 3.25 ± 1.39*
  1. HF heart failure, CO Cardiac output, PCWP pulmonary capillary wedge pressure, MAP mean aortic pressure, LVEDP left ventricular end-diastolic presssure Values are given as mean ± SD
  2. * Normal vs. HF (p <0.001)