Skip to main content

Table 2 Intraoperative and post-operative data comparison between groups

From: Clinical evaluation of percutaneous and intra-operative device closure of atrial septal defects under transesophageal echocardiographic guidance: one center experience and mid-term follow-up

 

Group A (n = 53)

Group B (n = 50)

P-value

Maximum diameter of ASD(mm)

16.4 ± 5.3

16.4 ± 5.2

0.98

Device size(mm)

22.4 ± 5.8

21.3 ± 6.6

0.38

D value

6.0 ± 1.6

4.7 ± 2.3

0.01

Rim of aortic valve (mm)

3.4 ± 1.2

2.2 ± 1.0

0.07

Table time(min)

20.72 ± 7.70

6.01 ± 1.03

0.01

Operation time(min)

28.70 ± 10.41

39.13 ± 6.03

0.01

ICU stay(hour)

4.12 ± 2.55

10.31 ± 3.64

0.01

Hospital time(d)

2.78 ± 0.9

4.7 ± 1.5

0.02

Death(%)

0

0

1

Bleeding/weigh(ml/kg)

0

12.29 ± 3.97

1

Wound infective

0

0

1

Hydrothorax

0

3

1

Residual shunt

4/50

7/50

0.52

Procedure successful

94.3(50/53)

94(47/50)

0.17

Successful 1 month(%)

98.11(52/53)

98(49/50)

0.37

Successful 3 month(%)

100

100

1

  1. D value: difference between the device size and the maximum diameter of ASD