Table 5 Multivariate regression analysis: predictors of echocardiographic outcomes at 6–12 months follow up

From: Converging rapid deployment prostheses with minimal access surgery: analysis of early outcomes

 

Coef

Standard error

95% CI

p value

LVEF

Mini-sternotomy

5.22

2.92

− 0.70 to 11.16

0.182

Euroscore

− 0.50

0.47

− 1.44 to 0.45

0.297

Prosthesis size

− 1.74

1.49

− 3.76 to − 1.29

0.043

Age

0.30

0.28

− 0.26 to 0.86

0.279

EOA

Mini access

− 0.04

0.10

− 0.25 to 0.16

0.670

Euroscore

− 0.03

0.01

− 0.05 to − 0.04

0.050

Prosthesis size

− 0.02

0.05

− 0.11 to 0.10

0.891

End diastolic volume

Mini-sternotomy

− 0.35

0.34

− 1.02 to − 0.05

0.050

Euroscore

− 0.37

0.18

− 0.73 to 0.04

0.070

Prosthesis size

− 0.04

0.13

− 0.33 to 0.24

0.759

BMI

− 0.04

0.04

− 0.12 to 0.05

0.377

BSA

0.30

0.85

− 1.51 to 2.11

0.729

End systolic volume

Mini-sternotomy

0.37

0.41

− 0.49 to 1.23

0.384

Euroscore

− 0.42

0.23

− 0.90 to 0.06

0.081

Prothesis size

0.02

0.18

− 0.36 to 0.39

0.922

BMI

0.01

0.06

− 0.12 to 0.13

0.938

BSA

0.18

1.22

− 2.41 to 2.76

0.886

  1. Bold type indicates statistical signifiance