Skip to main content

Table 2 Univariate and multivariable analysis of baseline and CT features

From: The risk factors for the failure of hook wire localization of ground glass nodules prior to thoracoscopic surgery

 

Univariable analysis

Multivariable analysis

OR

95% CI

P value

OR

95% CI

P value

Age

1.007

0.963–1.053

0.763

   

Sex

      

Male

1.0

     

Female

1.145

0.471–2.814

0.764

   

Smoke

      

No

1.0

     

Yes

1.347

0.528–3.440

0.533

   

Localization of multiple nodules

      

No

1.0

     

Yes

2.597

1.050–6.361

0.035

1.346

0.494–3.595

0.552

Location time (min)

0.956

0.898–1.019

0.166

   

Depth of nodule (mm)

0.910

0.850–0.973

0.006

0.942

0.875–1.014

0.113

Trans-fissure

      

No

1.0

     

Yes

4.896

1.489–13.939

0.005

2.168

0.613–6.773

0.199

Trans-emphysema

      

No

1.0

     

Yes

3.538

1.343–8.827

0.008

1.003

0.343–2.806

0.995

Diameter (mm)

1.020

0.912–1.141

0.731

   

Insertion position

      

Supine

1.0

     

Prone

2.304

0.605–8.767

0.221

   

lateral

1.686

0.445–6.396

0.442

   

Location

      

Upper and middle

1.0

     

Lower

0.860

0.356–2.077

0.737

   

Pneumothorax

      

No

1.0

     

Yes

10.326

3.414–44.684

 < 0.001

5.998

1.680–28.342

0.010

Pulmonary hemorrhage

      

No

1.0

     

Yes

1.552

0.909–2.497

0.083