Skip to main content
  • Oral presentation
  • Open access
  • Published:

The double orifice valve technique to treat tricuspid valve incompetence

Objectives

This aims to illustrate and report a straightforward tricuspid valve (TV) repair technique employed for moderate or severe functional (normal valve with dilated annulus) or for primary /organic (Ebstein’s anomaly, leaflet or chordal retraction/tethering, with annular dilatation) tricuspid valve incompetence and its long-term outcome.

Methods

The double-orifice valve technique was employed on 73 patients (mean age 52.6±23.2 years) with severe tricuspid regurgitation: 3 post-transplant iatrogenic chordal rupture, 23 Ebstein's anomaly, and 47 solated severe TV incompetence. The basic principle is to reduce the distance between the coapting leaflets by creating two orifices. The degree and extent of creating a double valve orifice was determined by considering the minimal body surface area (BSA)-related acceptable TV diameter. Repair was accomplished by ledgeted mattress sutures from the middle of the true anterior annulus to a spot on the opposite septal annulus avoiding injury to the Bundle of His.The annular apposition divides the TV into having a larger anterior and a smaller posterior orifices, enabling valve closure. In adults, the diameter of the anterior valve orifice should be 23 to 25 mm, and the posterior orifice should be 15-18 mm.

Results

At a mean follow-up of 4.1 years (range 1.5-12.4 years), there has been no reoperation for tricuspid valve insufficiency or stenosis. Reoperations done on 3 patients were indicated in one for aortic valve replacement 14 months postoperatively and in 2 for assist device implantation who eventually underwent heart transplantation 18 and 20 months aftert TV repair, respectively. Cumulative 12-year survival rate is 88%.

Conclusions

This technique is technically a straightforward repair to abolish TV incompetence with highly satisfactory results. It provides no pitfalls, if one keeps in mind the location of the conduction system, and neither residual regurgitation nor reoperation occurs.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to R Hetzer.

Rights and permissions

This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Reprints and permissions

About this article

Cite this article

Hetzer, R. The double orifice valve technique to treat tricuspid valve incompetence. J Cardiothorac Surg 8 (Suppl 1), O103 (2013). https://doi.org/10.1186/1749-8090-8-S1-O103

Download citation

  • Published:

  • DOI: https://doi.org/10.1186/1749-8090-8-S1-O103

Keywords