Skip to main content

Table 4 Correlation between of mean INR levels and thromboembolic or bleeding events

From: The effects of a low international normalized ratio on thromboembolic and bleeding complications in patients with mechanical mitral valve replacement

  All patients
r p
All Thromboembolic Events -0.197 0.022
Valve Thrombosis -0.147 0.089
Stroke -0.162 0.060
TIA -0.037 0.673
All Bleeding Events 0.206 0.016
Major Bleeding 0.144 0.096
Minor Bleeding 0.146 0.092
Total Events -0.020 0.822
  1. TIA: Transient Ischemic Attacks.
  2. Pearson correlation analysis.