Skip to main content

Table 4 Post-operative (discharge) parameters

From: Perceval sutureless bioprosthesis versus Perimount sutured bioprosthesis for aortic valve replacement in patients with aortic stenosis: a retrospective, propensity-matched study

 

Perimount, n=102

Perceval, n=102

P-value

Operative mortality

2.0% (2)

2.0% (2)

1.000

Need for hemofiltration or dialysis

1.0% (1)

2.9% (3)

0.313

Pacemaker implantation

7.8% (8)

5.9% (6)

0.580

Bleeding req. transfusion

2% (2)

2.9% (3)

0.667

Transient stroke

2.0% (2)

0% (0)

0.155

Permanent stroke

2.9% (3)

0% (0)

0.081

Return to theatre for bleeding / tamponade

5.9% (6)

3.9% (4)

0.517

  1. Values: % (n)
  2. for this variable, Perimount n=100, Perceval n=102