Health-related quality of life in children and adolescents undergoing intraoperative device closure of isolated perimembranous ventricular septal defects in southeastern China

Abstract

Objectives

To investigate the health-related quality of life (HRQOL) in children and adolescents who underwent intraoperative device closure of perimembranous ventricular septal defects (pmVSDs).

Methods

From October 2017 to January 2018, a total of 126 children and adolescents with isolated pmVSDs who underwent intraoperative device closure were enrolled in this study. We used the Pediatric Quality of Life Inventory Measurement Models 4.0 generic core scales to measure HRQOL 24 h before the operation and three months and one year after surgery.

Results

A total of 126 patients were successfully occluded. No severe complications occurred during the operative time, and 1 case of Mobitz type I atrioventricular block (AVB) and 1 case of complete cAVB occurred during the postoperative period. Compared with the data before the operation, the total score and five domain scores, including physical, psychosocial, emotional, social and psychological functioning, were significantly higher at three months after the operation. In addition, the total score, physical functioning score, and the psychosocial functioning score at the 1-year follow-up were even higher than those at 3 months after the operation.

Conclusions

The present study suggests that intraoperative device closure of pmVSD could improve health-related quality of life in children/adolescents and that the improvement may progress as the time after the operation increases. Further studies should concentrate on comparisons with other medical methods, larger samples, and longer follow-up periods.

Peer Review reports

Introduction

Ventricular septal defect (VSD) is one of the most common congenital cardiac defects in children and adolescents [1]. Surgical repair of VSD with cardiopulmonary bypass (CPB) has been a routine procedure for most patients with VSD, providing direct visual access to the defects. However, surgical repair is inevitably associated with many complications and surgical scars, which may impact neurodevelopmental, psychosocial, and physical functioning and diminish quality of life, especially for children and adolescents [2,3,4,5,6,7]. With the development of various occluders, transcatheter device closure of VSD has gradually become an alternative treatment and has been widely applied in the last decade, especially for perimembranous VSD. The transcatheter technique is acceptable for patients with an excellent rate of closure and only leaves a puncture on the surface, which offers an impressive cosmetic result [8, 9]. Recently, intraoperative device closure of VSD under the guidance of transesophageal echocardiography (TEE) has been widely and successfully used in China, and previous reports have already proven its feasibility and safety [10,11,12]. With regard to the incidence of a particular functional impairment in the cardiac population, health-related quality of life (HRQOL) has already been used as an essential assessment of cardiac operations [13,14,15]. A literature search did not reveal any report focusing on HRQOL after intraoperative device closure of pmVSD in children and adolescents. The present study aimed to explore HRQOL before and after intraoperative device closure of pmVSD in children and adolescents using the Pediatric Quality of Life Inventory (PedsQLTM) 4.0 generic core scale as an evaluation tool.

Materials and methods

Patients

The participants were enrolled in our cardiac department from October 2017 to January 2018. The inclusion criteria were as follows: restrictive perimembranous VSD, clinical and ECG evidence of significant left-to-right shunts and isolated VSD with the size of VSD ranging from 3 to 7 mm, and (or) a certain degree of heart chamber enlargement and (or) mild to moderate pulmonary hypertension. The exclusion criteria included the following: nonrestrictive VSD; size of VSD larger than 8 mm or smaller than 2 mm, especially those with large VSD; and high pulmonary hypertension coexisting other cardiac anomalies. Children or adolescents who had a developmental disability, intelligence defect or other condition that might affect HRQOL were also excluded from this study. The preoperative baseline characteristics of patients enrolled in this study are shown in Table 1.

Table 1 Preoperative baseline characteristics

Operative technique

TEE was used to assess the VSD position and the circumferential margins, especially their relationship with the aortic valve and tricuspid valve. A minimal incision (2–3 cm) was made through a lower partial median sternotomy. The pericardium was suspended to expose the right ventricle. The puncture site of the right ventricle was determined by indenting the free wall under TEE guidance to ensure that the puncture site was perpendicular to the defect and free of internal cardiac tissue. The guide wire was introduced into the right ventricle and then through the VSD defect to the left ventricle. A delivery sheath was introduced into the left ventricle through the guide wire to establish a delivery pathway. Then, the wire and the inner dilator were removed. The occluder was loaded into the delivery sheath with the help of a loading cable. Then, the occluder was advanced to the tip of the sheath, and the left disc was first deployed followed by the right disc. TEE assessment was performed to detect residual shunt or valve dysfunction [10,11,12].

Instruments

We used the PedsQLTM 4.0 generic core scale to assess health-related QOL in this study. This instrument evaluates five aspects: physical functioning, psychological functioning, emotional functioning, social functioning, and school functioning. We rated the items on a five-point linear scale among participants aged 8–18 years (0 = never a problem; 1 = almost never an issue; 2 = sometimes a problem; 3 = often a problem; 4 = almost always a problem) and on a 3-point scale among participants aged 5–7 years (0 = not at all a problem; 2 = sometimes a problem; 3 = always a problem). Items of this instrument were reverse scored and linearly transformed into a 0–100 scale. A higher score suggests better HRQOL.

Procedure

Two independent cardiac doctors were responsible for this investigation. We obtained the demographic and operation data of the participants through the electronic medical database. For the measurement of HRQOL changes before and after intraoperative device closure of pmVSD, the investigation was conducted at three time points: 24 h before the operation and 3 months and 1 year after the surgery. The first investigation was conducted in the meeting room, and the other two were performed at the hospital outpatient department when patients returned for physical examination. For participants aged 5–7 years old, the interviewer asked about the frequency of problems in the past month and filled in the form. For participants aged 8–14 years old, participants filled in the questionnaire alone.

Statistical analysis

Continuous variables are expressed as x ± s; the t-test or analysis of variance was applied for continuous variables, and the χ2 or Fisher’s test was applied for categorical variables. A p value < 0.05 was defined as statistically significant. We used SPSS 17.0 software (SPSS Inc., Chicago, Illinois, United States of America) to analyze the data.

Results

In total, 126 patients were successfully closed by undergoing intraoperative device closure of pmVSD. No patients were required to undergo surgical repair. Follow-up items included cardiac function, TTE, and electrocardiograph (ECG). Only 1 case of Mobitz type I atrioventricular block (AVB) and 1 case of late-onset complete AVB were recorded. A permanent pacemaker was installed in this patient with complete AVB. No other severe complications, including death, device disruption or failure, endocarditis, thrombosis, aortic valve distortion and permanent rhythm disturbances, occurred in the hospital stay or during 12-month follow-up period. The details of the follow-up results are shown in Table 2.

Table 2 Post-operative and follow-up complication results

The health-related QOL change and comparison results are presented in Table 3. Compared with scores before surgery, the total score and the scores of the five domains, physical functioning, psychosocial functioning, emotional function, social functioning, and psychological functioning, were significantly higher at 3 months after the operation (P < 0.05). In addition, the total score, physical functioning score, and psychosocial functioning score were even higher 1 year after the operation (P < 0.05).

Table 3 Score change and comparison of health-related QOL

Discussion

A ventricular septal defect is the most common congenital cardiac defect. Surgical repair under CPB was considered the gold-standard treatment for the closure of VSD, but this method remained limited by cosmetic problems and the potential risk of CPB [16, 17]. Transcatheter device closure of VSD showed a promising result and mid-term follow-up in recent reports [8, 9]. Yang and his colleagues reported a series of 848 patients with perimembranous VSD undergoing transcatheter device closure with a success rate of 98.1%, and there were only two cases of cAVB requiring pacemaker implantation during follow-up. The authors concluded that transcatheter pmVSD closure could be performed safely and successfully with low morbidity and mortality [15]. Wang L and coworkers reported a series of 525 children (aged between 2 and 12 years) with pmVSD who underwent transcatheter device closure. The successful device closure rate was 95.6%, and a total of three major adverse events (0.6%) were reported [18]. Compared with a conventional surgical procedure, transcatheter device closure only leaves a puncture and does not require CPB, preventing patients from myocardial reperfusion injury and resulting in a rapid recovery. However, transcatheter device closure was limited by potential vascular injury and exposure to X-rays. There were also technical challenges when applied to infants or patients with a weight below 10 kg [19]. Under these conditions, intraoperative device closure of VSD developed from the above two treatments. Xing and his colleagues reported a series of 458 patients undergoing minimally invasive transthoracic device closure of VSD with a success rate of 96.29% and no severe complications or death during follow-up in 2015 [10]. Our report also showed that a series of 1033 patients were successfully occluded with this procedure with little difficulty. We concluded that the intraoperative device closure of VSD on a beating heart was a safe and feasible alternative to conventional surgical repair and transcatheter device closure [20]. The comparisons among surgical repair with CPB, intraoperative device closure and transcatheter device closure of VSD regarding risks and benefits were summarized in table 4.12(the data derived from our team’s previous report).

Table 4 The comparisons among surgical repair, intraoperative device and transcatheter device closure of VSD regarding risks and benefits based on the previous report

In this study, our follow-up results were consistent with previous reports. A total of 126 patients were all successfully occluded, and no patient was required to undergo surgical repair. Complete AVB is a significant complication for device closure of VSD and may significantly affect the quality of life of patients, but the exact mechanism remains unclear. This may result from the different understanding of cardiac anatomy among operators and the distance of the delivery pathway. The incidence of transient cAVB ranged from 1 to 5% in patients undergoing transcatheter device closure of VSD [21,22,23]. Only 1 case of late-onset complete AVB occurred during the follow up, and a permanent pacemaker was inserted into this patient. We attribute this impressively low incidence of cAVB to the following two reasons: First, this procedure provided a shorter and direct distance of delivery pathway causing less mechanical trauma/compression and second, we chose a suitable size of the device for each patient, thus minimizing pressure on the tricuspid annulus where the AV node lies. This study also demonstrated that intraoperative device closure was a safe and feasible alternative for select patients with pmVSD.

A literature search was unable to identify any reports that focused on the HRQOL of patients who underwent intraoperative device closure for pmVSD. The investigation of HRQOL in children and adolescents with congenital VSD would provide complementary information for the decisions of health professionals. In this study, we used the Pediatric Quality of Life Inventory Measurement Models 4.0 generic core scales to measure the health-related QOL. Since Varni JW and his coworkers first proposed the Pediatric Quality of Life Inventory Measurement Models 4.0 generic core scale in 2001, this instrument has been widely used and proven to be reliable and valid [24]. Matza and coworkers emphasized when choosing a questionnaire that the minimum age that children can answer questions about quality of life and the format of the instrument suitable for the level of understanding of each age group should be taken into consideration [25]. Varni et al. reported in 2007 that children as young as 5 years old can reliably and validly self-report their HRQOL [26]. In addition, the PedsQLâ„¢ 4.0 Generic Core Scales have already been widely applied in evaluating the quality of life of patients with congenital heart disease [27, 28]. Hao Y and his colleagues proposed a Chinese version of the Pediatric Quality of Life Inventory 4.0 generic core scales and concluded that this instrument had acceptable psychometric properties with the exception of the construct validity tested by confirmatory factor analysis and the internal reliability for self-report [29].

Thus, we chose this instrument in our study and assumed that intraoperative device closure could improve HRQOL in children/adolescents with isolated pmVSD. We found that the total score and the five domain scores, physical, psychosocial, emotional, social and emotional functioning, were significantly higher at the three-month follow-up compared with the scores before the operation (P < 0.05). Such results indicated that the patient’s quality of life was significantly improved in the short term after surgery. However, the scores for emotional functioning, social functioning, and school functioning were not significantly higher than the scores at 12 months after the operation. However, the total score, physical functioning score and psychosocial functioning score at 12 months were all even higher than the scores at 3 months after the operation. This encouraging trend suggested that intraoperative device closure of pmVSD on a beating heart can improve health-related QOL in children/adolescents, and this improvement seems to progress as time goes on. We contributed this improvement to the lasting improvement in cardiac function and the low complication and high closure rate of intraoperative device closure of pmVSD in our institution. Satisfactory surgical results also significantly improved the patient’s quality of life. However, it is not enough to conclude whether this improvement would continue and how long it could last. We could not analyze the subpopulation to identify high-risk factors that could affect postoperative HRQOL due to the limited sample size in this study. Patients undergoing intraoperative device closure of pmVSD deserve more attention for their prognosis and quality of life.

The following factors limited this study. First, this study had a small sample size and was only conducted in one institution. Second, the follow-up period lasted only 12 months. A larger sample and longer follow-up are required for a future study. Third, there was no control group involving children/adolescents with isolated VSD undergoing other treatments, including transcatheter device closure or surgical repair, to which to compare the results. Thus, in a future study, to elucidate the impact of intraoperative device closure of VSD on HRQOL, a control group would be needed.

Conclusion

In conclusion, intraoperative device closure of pmVSD on a beating heart can improve health-related QOL in children/adolescents. The improvement of QOL increased as time passed during the follow-up period. Further studies should focus on the comparison between patients undergoing intraoperative device closure of pmVSD with patients with VSD undergoing other treatments or patients with VSD who did not undergo therapy.

Availability of data and materials

Data sharing not applicable to this article as no data sets were generated or analyzed during the current study.

Abbreviations

AVB:

Atrioventricular block

CPB:

Cardiopulmonary bypass

HRQOL:

Health-related quality of life

TEE:

Transesophageal echocardiography

VSD:

Ventricular septal defects

References

  1. Roos-Hesselink JW, Meijboom FJ, Spitaels SE, Van Domburg R, Van Rijen EH, Utens EM, Bogers AJ, Simoons ML. The outcome of patients after surgical closure of ventricular septal defect at a young age: longitudinal follow-up of 22-34 years. Eur Heart J. 2004;25(12):1057–62.

    Article  CAS  Google Scholar 

  2. Wernovsky G, Stiles KM, Gauvreau K, Gentles TL, du Plessis AJ, Bellinger DC, Walsh AZ, Burnett J, Jonas RA, Mayer JE Jr, Newburger JW. Cognitive development after the Fontan operation. Circulation. 2000;102:883–9.

    Article  CAS  Google Scholar 

  3. Bellinger DC, Wypij D, du Plessis AJ, Rappaport LA, Jonas RA, Wernovsky G, Newburger JW. Neurodevelopmental status at eight years in children with dextro-transposition of the great arteries: the Boston circulatory arrest trial. J Thorac Cardiovasc Surg. 2003;126:1385–96.

    Article  Google Scholar 

  4. Casey FA, Sykes DH, Craig BG, Power R, Mulholland HC. Behavioral adjustment of children with surgically palliated complex congenital heart disease. J Pediatr Psychol. 1996;21:335–52.

    Article  CAS  Google Scholar 

  5. Cassidy AR, Ilardi D, Bowen SR, Hampton LE, Heinrich KP, Loman MM, Sanz JH, Wolfe KR. Congenital heart disease: a primer for the pediatric neuropsychologist. Child Neuropsychol. 2018;24(7):859–902.

    Article  Google Scholar 

  6. Davis CC, Brown RT, Bakeman R, Campbell R. Psychological adaptation and adjustment of mothers of children with congenital heart disease: stress, coping, and family functioning. J Pediatr Psychol. 1998;23:219–28.

    Article  CAS  Google Scholar 

  7. Mahle WT, McBride MG, Paridon SM. Exercise performance after the arterial switch operation for D-transposition of the great arteries. Am J Cardiol. 2001;87:753–8.

    Article  CAS  Google Scholar 

  8. Tucker EM, Pyles LA, Bass JL, Moller JH. Permanent pacemaker for atrioventricular conduction block after operative repair of perimembranous ventricular septal defect. J Am Coll Cardiol. 2007;50(12):1196–200.

    Article  Google Scholar 

  9. Bass JL, Kalra GS, Arora R, Masura J, Gavora P. Initial human experience with the Amplatzer perimembranous ventricular septal occluder device. Catheter Cardiovasc Interv. 2003;58:238–45.

    Article  Google Scholar 

  10. Xing Q, Pan S, An Q, Zhang Z, Li J, Li F, Wu Q, Zhuang Z. Minimally invasive perventricular device closure of perimembranous ventricular septal defect without cardiopulmonary bypass: multicenter experience and mid-term follow-up. J Thorac Cardiovasc Surg. 2010;139(6):1409–15.

    Article  Google Scholar 

  11. Wang S, Zhuang Z, Zhang H, Zhen J, Lu Y, Liu J, Xu Z. Perventricular closure of perimembranous ventricular septal defects using the concentric occluder device. Pediatr Cardiol. 2014;35(4):580–6.

    Article  CAS  Google Scholar 

  12. Fang GH, Chen Q, Hong ZN, Lin ZW, Zhang GC, Cao H, Chen LW. The comparison of Perventricular device closure with Transcatheter device closure and the surgical repair via median Sternotomy for Perimembranous ventricular Septal defect. Ann Thorac Cardiovasc Surg. 2018;24(6):308–14.

    Article  Google Scholar 

  13. Silva AM, Vaz C, Areias ME, Vieira D, Proença C, Viana V, Moura C, Areias JC. Quality of life of patients with congenital heart diseases. Cardiol Young. 2011;21(6):670–6.

    Article  Google Scholar 

  14. Latal B, Helfricht S, Fischer JE, Bauersfeld U, Landolt MA. Psychological adjustment and quality of life in children and adolescents following open-heart surgery for congenital heart disease: a systematic review. BMC Pediatr. 2009;9:6.

    Article  Google Scholar 

  15. Yang J, Yang L, Wan Y, Zuo J, Zhang J, Chen W, Li J, Sun L, Yu S, Liu J, Chen T, Duan W, Xiong L, Yi D. Transcatheter device closure of perimembranous ventricular septal defects: mid-term outcomes. Eur Heart J. 2010;31(18):2238–45.

    Article  Google Scholar 

  16. Schipper M, Slieker MG, Schoof PH, Breur JM. Surgical repair of ventricular Septal defect; contemporary results and risk factors for a complicated course. Pediatr Cardiol. 2017;38(2):264–70.

    Article  Google Scholar 

  17. Heiberg J, Ringgaard S, Schmidt MR, Redington A, Hjortdal VE. Structural and functional alterations of the right ventricle are common in adults operated for ventricular septal defect as toddlers. Eur Heart J Cardiovasc Imaging. 2015;16(5):483–9.

    Article  Google Scholar 

  18. Wang L, Cao S, Li J, Yang L, Liu Y, Ren J, Ma Q, Xing H, Li D, Tian D, Wan Y, Yu S, Chen T, Yang X, Yang J. Transcatheter closure of congenital perimembranous ventricular septal defect in children using symmetric occluders: an 8-year multiinstitutional experience. Ann Thorac Surg. 2012;94(2):592–8.

    Article  Google Scholar 

  19. Butera G, Piazza L, Saracino A, Chessa M, Carminati M. Transcatheter closure of membranous ventricular Septal defects-old problems and new solutions. Interv Cardiol Clin. 2013;2(1):85–91.

    PubMed  Google Scholar 

  20. Chen Q, Hong ZN, Zhang GC, Chen LW, Zhang QL, Lin ZW, Cao H. Intraoperative device closure of isolated ventricular Septal defects: experience on 1,090 cases. Ann Thorac Surg. 2018;105(6):1797–802.

    Article  Google Scholar 

  21. Bai Y, Xu XD, Li CY, Zhu JQ, Wu H, Chen SP, Chen F, You XH, Zhao XX, Qin YW. Complete atrioventricular block after percutaneous device closure of perimembranous ventricular septal defect: a single-center experience on 1046 cases. Heart Rhythm. 2015;12(10):2132–40.

    Article  Google Scholar 

  22. Walsh MA, Bialkowski J, Szkutnik M, Pawelec-Wojtalik M, Bobkowski W, Walsh KP. Atrioventricular block after transcatheter closure of perimembranous ventricular septal defects. Heart. 2006;92(9):1295–7.

    Article  CAS  Google Scholar 

  23. Yang R, Kong XQ, Sheng YH, Zhou L, Xu D, Yong YH, Sun W, Zhang H, Cao KJ. Risk factors and outcomes of post-procedure heart blocks after transcatheter device closure of perimembranous ventricular septal defect. JACC Cardiovasc Interv. 2012;5(4):422–7.

    Article  Google Scholar 

  24. Varni JW, Seid M, Kurtin PS. PedsQL™ 4.0: reliability and validity of the pediatric quality of life InventoryTM version 4.0 generic core scales in healthy and patient populations. Med Care. 2001;39:800–12.

    Article  CAS  Google Scholar 

  25. Matza LS, Swensen AR, Flood EM, Secnik K, Leidy NK. Assessment of health-related quality of life in children: a review of conceptual, methodological, and regulatory issues. Value Health. 2004;7(1):79–92.

    Article  Google Scholar 

  26. Varni JW, Limbers CA, Burwinkle TM. How young can children reliably and validly self-report their health-related quality of life?: An analysis of 8,591 children across age subgroups with the PedsQLâ„¢ 4.0 Generic Core Scales. Health Qual Life Outcomes. 2007;5:1.

    Article  Google Scholar 

  27. Uzark K, Jones K, Burwinkle TM, Varni JW. The pediatric quality of life inventory™ in children with heart disease. Prog Pediatr Cardiol. 2003;18:141–9.

    Article  Google Scholar 

  28. Uzark K, Jones K, Slusher J, Limbers CA, Burwinkle TM, Varni JW. Quality of life in children with heart diseases as perceived by children and parents. Pediatrics. 2008;121:e1060–7.

    Article  Google Scholar 

  29. Hao Y, Tian Q, Lu Y, Chai Y, Rao S. Psychometric properties of the Chinese version of the pediatric quality of life inventory 4.0 generic core scales. Qual Life Res. 2010;19(8):1229–33.

    Article  Google Scholar 

Download references

Acknowledgements

We highly acknowledge the contribution by the participating doctors: Dao-zhong Chen, Feng Lin, Qi-min Wang, Han-fan Qiu, Xue-shan Huang, Dong-shan Liao, Xiao-fu Dai, Zeng-chun Wang.

Funding

This research was sponsored by Chinese national and Fujian provincial key clinical specialty construction programs.

Author information

Authors and Affiliations

Authors

Contributions

QC, J-sH and S-tH designed the study, participated in the operation, and drafted the manuscript. K-pS and Z-nH collected the clinical data and performed the statistical analysis. L-wC and Y-rK provide financial and technical support. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Qiang Chen.

Ethics declarations

Ethics approval and consent to participate

The present study was approved by the ethics committee of Fujian Medical University, China and adhered to the tenets of the Declaration of Helsinki. Additionally, written informed consent was obtained from the relatives of the patients.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Huang, JS., Huang, ST., Sun, KP. et al. Health-related quality of life in children and adolescents undergoing intraoperative device closure of isolated perimembranous ventricular septal defects in southeastern China. J Cardiothorac Surg 14, 218 (2019). https://doi.org/10.1186/s13019-019-1040-6

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13019-019-1040-6

Keywords