Skip to main content

Nonstandard usage of a left ventricular assist device in a patient with severe heart failure complicated by pulmonary artery thrombosis - case report

Abstract

Background

Heart failure complicated by pulmonary embolism is an extremely rare condition described in the literature. We report a case of very young patient with advanced heart failure against the background of dilated cardiomyopathy of unknown etiology with the presence of blood clots in both ventricles.

Case presentation

The course of treatment was complicated by acute pulmonary embolism. In emergency setting the patient was qualified for combine surgery pulmonary embolization and implantation of a continuous flow pump as a bridge for heart transplantation. The post-operative course is described in detail as well as reimplantation of the pump due to early thrombosis.

Conclusions

Performed surgical procedures combined with alteration in anticoagulant drugs was sufficient to stabilize the clinical condition.

Peer Review reports

Introduction

Despite considerable advances in the treatment of severe heart failure, long-term survival is poor. Therapeutic schemes are effective for most clinical cases. However, some of them require non-standard procedures.

Case report

An 18-year-old patient was admitted to the ward with severe heart failure with a background of dilated cardiomyopathy of unknown aetiology. On admission day he was hemodynamically stable, however, during the night patient developed dyspnoea accompanied by haemodynamic instability and cardiogenic shock. In the echocardiography, two mobile thrombi of 20x10mm were visualised in both ventricles (Fig. 1). The bases of the thrombi were attached to the endocardium. The left ventricular ejection fraction was 18%. Additionally, a pulmonary embolism was revealed in the computed tomography scan (Fig. 2). Considering the Wells scale (original version), the patient obtained < 4 points. In laboratory tests there were no significant signs of coagulation disorders besides mild fibrinogen elevation to 420 mg/dl and 1.99 μg/ml of D-dimer. The D-dimer elevation would indicate the forming of a thrombus, however, the fibrinogen levels suggests it was of a low intensity.

Fig. 1
figure 1

Trombus formation in left and right ventricle in echocardiography. RVOT - right ventricular outflow tract,, LV – left ventricle

Fig. 2
figure 2

The saddle embolism in the lumen of the right upper lobar artery (a and b)

Regarding the patient’s deteriorating condition, a decision was made to implant, a left ventricular assist device (LVAD) as a bridge to transplantation. The removal of the thrombus from the left ventricle and a pulmonary embolectomy were performed simultaneously.

Two days after implantation, a more than two-fold pump power consumption increase and a lactate dehydrogenase concentration exceeding the norm (up to 5775 IU/l) was observed. This suggested haemolysis within the implanted LVAD. Thrombosis occurred despite the implementation of anticoagulant therapy. In regard to the postoperative condition, it wasn’t possible to apply thrombolytic therapy. Intravenous, anticoagulant heparin treatment proved to be ineffective. Considering the deteriorating condition and confirmation of active coagulation within the device by echocardiography, the decision was made to urgently substitute the LVAD.

After reoperation, paroxysmal atrial fibrillation was observed, which was controlled with intravenous amiodarone. The symptoms of a respiratory tract infection required microbiological diagnosis. In the sputum culture, abundant growth of Klebsiella pneumoniae ESBL (+) and Candida dubliniensis was detected. Due to postoperative acute renal failure and anuria, haemodiafiltration was carried out. These events had a negative impact on the patient’s condition and extended his rehabilitation. During the hospitalisation, an autoimmune disease was suspected. The suspicion was initially confirmed by the positive result of lupus anticoagulant (1.3, reference value > 1.2). However, negative results of anti-nuclear antibodies, anti-neutrophil cytoplasmic antibodies and other characteristic for lupus antibodies may suggest remission or absence of the ailment. The presence of anti-DFS70 was also not demonstrated. In the presence of this antibody, the chance of rheumatic or autoimmune diseases is lower. With regard to the full picture, we couldn’t exclude or confirm an autoimmune disease.

Discussion

Heart failure complicated by pulmonary embolism is an extremely rare condition described in the literature. In the following case, it is reasonable to perform the procedures of simultaneous removal of thrombi and LVAD implantation. In the group of young patients affected by pulmonary embolism it seems reasonable to undertake an in-depth diagnosis. An aspect worth considering in the context of distant therapy, is the possible impact of the genetic load on a predisposition to further thromboembolic complications. An important factor in the prevention of early cardiovascular disease is the control of systemic lupus erythematosus, which significantly changes the dynamic of the endovascular endometrium and may worsen the prognosis [1,2,3].

Conclusion

Long-term VAD treatment was effective in this patient with severe heart failure, despite the ventricular thrombosis and acute pulmonary embolisation. In our experience, the combined surgical procedure of implantation of a left ventricular assist device and a pulmonary embolectomy was the only possible way to save the patient’s life. The infection in the respiratory system and the suspected autoimmune disease additionally complicated the course of acute heart failure due to the presence of thrombus formation in the ventricular cavities.

Availability of data and materials

Not applicable. The datasets analyzed during the study are available from the corresponding author on reasonable request.

Abbreviations

LVAD:

Left ventricular assist device

References

  1. Kreps A, Paltoo K, McFarlane I. Cardiac manifestations in systemic lupus Erythematosus: a case report and review of the literature. Am J Med Case Rep. 2018;6(9):180–3.

    Article  Google Scholar 

  2. Cervera R, Font J, Paré C, et al. Cardiac disease in systemic lupus erythematosus: prospective study of 70 patients. Ann Rheum Dis. 1992;51(2):156–9.

    Article  CAS  Google Scholar 

  3. Kim CH, Al-Kindi SG, Jandali B, et al. Incidence and risk of heart failure in systemic lupus erythematosus. Heart. 2017;103:227–33.

    Article  Google Scholar 

Download references

Acknowledgements

Not applicable.

Funding

Not applicable.

Author information

Authors and Affiliations

Authors

Contributions

J.P – case report concept, critical revision of the article, final approval of manuscript, S.L – assembly of data, data analysis and interpretation, writing article, M.S - assembly of data, data analysis and interpretation, writing article, P.N - critical revision of the article, final approval of manuscript.

Corresponding author

Correspondence to Szymon Leonik.

Ethics declarations

Ethics approval and consent to participate

The Case Report is exempt from the Ethical Approval based on the basis that this type of study is the retrospective analysis. Patient consent was gave during admission to the hospital.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Pacholewicz, J., Leonik, S., Sojka, M. et al. Nonstandard usage of a left ventricular assist device in a patient with severe heart failure complicated by pulmonary artery thrombosis - case report. J Cardiothorac Surg 15, 123 (2020). https://doi.org/10.1186/s13019-020-01169-0

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13019-020-01169-0

Keywords