5-year results of a newly implemented mechanical circulatory support program for terminal heart failure patients in a Swiss non-cardiac transplant university hospital

Abstract

Background

In Switzerland, long-term circulatory support programs have been limited to heart transplant centers. In 2014, to improve the management of patients with end-stage heart failure not eligible for transplantation, we implemented a left ventricular assist device (LVAD) program for destination therapy at the University Hospital of Basel.

Methods

We described the program set-up with practical aspects. Patients aged 65 and above with therapy refractory end-stage heart failure without major contraindication for LVAD implantation were included. Younger patients with bridge-to-candidacy profile were also considered. Using the Kaplan-Meier estimate, we retrospectively analyzed the overall survival and freedom from major adverse events after LVAD implantation. We compared our results to internationally reported data.

Results

Between October 2014 and September 2019, 16 patients received an LVAD in our center. The mean age at implantation was 67.1 years. The mean EuroSCORE II was 24.4% and the median INTERMACS level was 4. Thirteen patients received an LVAD as destination therapy and three patients as bridge-to-candidacy. The overall survival was 87.5 and 70% at 1 and 2 years, respectively. Freedom from stroke was 81.3% at 1 and 2 years. Freedom from device infection was 67.7 and 58.7% at 1 and 2 years, respectively. Freedom from gastrointestinal bleeding was 75 and 56.3% at 1 and 2 years, respectively. Freedom from readmission was 50 and 31.3% and at 6 months and 1 year, respectively.

Conclusions

The Basel experience demonstrated the possible implementation of an LVAD program for destination therapy or bridge-to-candidacy in a non-transplant comprehensive heart-failure center with midterm survival results and freedom from major adverse events comparable to international registries. Patient selection remains crucial.

Trial registration

This study was registered on the ClinicalTrials.gov database (NCT04263012).

Peer Review reports

Background

Initially limited to patients with worsening end-stage heart failure awaiting heart transplant (HTx), left ventricular assist devices (LVADs) have undergone a tremendous development over the past three decades. Reduction in size and advancements in device safety have drastically improved patient survival and quality of life after LVAD implantation [1]. Due to the shortage of donor organs, bridge-to-recovery, bridge-to-decision, bridge-to-candidacy, and destination therapy (DT) have become commonplace practices [2]. In 2012, the American Heart Association recognized LVAD for DT in selected patients as a Class I recommendation, thereby impacting reimbursement policies in Switzerland [3]. Two years later, DT was granted with additional compensation nationally. Switzerland counts eight million inhabitants and five university hospitals, of which Zürich, Bern, and Lausanne. The latter offer HTx and long-term mechanical circulatory support. The University Hospital Basel (USB) is a 750-bed hospital with 7200 employees, is rated as a non-transplant, comprehensive heart-failure center (CHFC) and had performed HTx until 2005. From 2013, evidence of a growing heart transplant waiting list in our country prompted us to strengthen our heart failure treatment and extend our armamentarium [4]. As a non-transplant CHFC, we decided to prioritize patients aged 65 and above by implementing a mechanical-circulatory-support program for DT. The purpose of this study was to describe the initial set-up of an LVAD program, focusing on its interdisciplinary and comprehensive aspects, and share our 5-year clinical results.

Methods

Building up the core-team of the LVAD program

When planning an LVAD program, team-player selection is crucial. The team members must be willing to uphold a strong professional interdisciplinary experience. The LVAD core-team included heart-failure cardiologists, cardiac surgeons, cardiac anesthesiologists, intensivists, perfusionists, intensive care nurses, and ward nurses. We believe the most important position in an LVAD program to be the LVAD coordinator. This partner must be selected very carefully since LVAD coordination is the glue between all actors and disciplines. Moreover, the LVAD coordinator is in close contact with the patients and their relatives and coordinates the complex network of out-patient care. This network includes among others: general practitioners, dentists, rehabilitation-hospitals, home based nursing, and LVAD industry partners.

Device selection, training, program setup and structure in brief

In 2013, while developing the program, we evaluated two different LVAD systems available on the market: HeartMate II (Abbott, Chicago, IL, USA), an axial continuous-flow pump and HeartWare HVAD (Medtronic, Minneapolis, MN, USA), a centrifugal continuous-flow pump. The latter presented the most modern propulsion concept. We opted for the HeartWare HVAD due to its recent promising clinical results, advanced hard- and software technology and its ease of implantation owing to smaller internal components [5]. Until October 2018, we implanted exclusively HeartWare HVAD. From 2019, influenced by the encouraging results from the MOMENTUM 3 trial, we switched to the next generation centrifugal pump HeartMate 3 (Abbott, Chicago, IL, USA) [6].

A group of six team members including an advanced heart failure cardiologist, cardiac surgeon, cardiac anesthesiologist, intensive care specialist, perfusionist, and the LVAD coordinator visited the Heart and Diabetes Center of Bad Oeynhausen (North Rhine-Westphalia, Germany). This center is one of the world’s largest in terms of mechanical circulatory support experience. Interviews of its LVAD program members, together with attendance of an LVAD implantation, made an important contribution to the architecture of our program. We further organized visitations of other international centers with extensive LVAD experience to gather a maximum amount of knowledge. In Basel, selected physicians and nurses from the cardiac surgery ward, the intensive care unit (ICU), the emergency department, and the operating theatre started an extensive in-house training.

Patient selection, device implantation and postoperative follow-up

A multidisciplinary team evaluated patients with terminal heart failure and severely impaired exercise capacity despite optimal medical therapy as assessed by ergometry and 6-min walk test [7, 8]. The patients were not eligible for transplant because of either advanced age or non-modifiable comorbidities impacting their life expectancy (e.g., malignancy). We also considered younger candidates with bridge-to-candidacy profile, i.e. not eligible for transplant at the time of insertion due to modifiable comorbidities (e.g., morbid obesity). These latter candidates might eventually be addressed to a nearby transplantation center. We excluded patients with a life expectancy shorter than 12 months, younger than 18, with active infections, or with irreversible hepatic, renal, or neurological disorders. Further exclusion criteria were poor treatment compliance, psychiatric limitations, and poor social network. The preoperative check-up consisted of the following examinations: complete blood count and blood chemistry, computed angiography scan of the thorax, right- and left-heart catheterization, transthoracic echocardiography (including bubble study to exclude intra-cardiac shunts and left ventricular thrombi), carotid Doppler ultrasound, and dental exam. We evaluated the risk of postoperative right ventricular (RV) failure using predictive models [9, 10]. Patients with high probability of requiring RV assistance were not integrated in the elective destination therapy program. Patients with prior gastrointestinal bleeding had to undergo a gastroscopy and a colonoscopy. Additionally, the candidates had to consult a psychologist as well as a palliative care specialist to circumscribe their needs, desires, and expectations regarding the treatment. Finally, patients were included only upon acceptance from all core-team members.

The LVAD coordinator organized all necessary examinations and the implantation procedure itself. The LVAD coordinator was responsible for teaching the patients how to handle the device and its components (batteries, etc.), and how to deal with alarms. The patients ‘near-relatives as well as the hospital staff, rehabilitation staff and out-of-hospital caregivers were also instructed.

The program officially started in October 2014. The first implantation was performed with assistance of an external consultant cardiac surgeon with extensive experience in LVAD implantation. In the peri- and early postoperative phase, RV function was evaluated using both hemodynamic (such as central venous pressure, pulmonary pressures, and RV stroke work index) and echocardiographic parameters (such as RV size, contractility of the free wall, tricuspid annulus plane systolic excursion, tricuspid insufficiency, and position of the ventricular septum). A Swan-Ganz catheter was systematically inserted prior to surgery and left until hemodynamic stabilization. Transesophageal echocardiography was liberally performed until acute RV failure had been ruled-out and the patient had been weaned from inotropic drugs. In addition to adrenalin and intravenous milrinone, nebulized NO and/or iloprost were routinely administered to lower the pulmonary resistance and support the RV. After initial stabilization at the ICU, patients were transferred to the ward. There, we continued the educational program until patients could fully handle the device and batteries. We provided anticoagulation with intravenous heparin and subsequently with vitamin K antagonists in combination with Aspirin. To prevent cerebrovascular events, we targeted a mean arterial blood pressure below 85 mmHg [11]. We defined an internal protocol based on chlorhexidine disinfection and silver-coated cellulose for the driveline dressing. After discharge, all patients participated in a rehabilitation program in an institution specialized for heart-and-lung rehabilitation. After returning home, patients were monitored by the LVAD coordinator monthly. They consulted the cardiologist and the cardiac surgeon monthly during the first 6 months and at least quarter yearly subsequently. The cardiologist performed a transthoracic echocardiography to assess the right heart function and the competency of the valves. Based on clinical assessment, device readouts, and echocardiographic ramp tests if required, LVAD parameters were regularly adjusted to the patients’ needs.

We established a 24/7/365 directed phone chain and a standard-of-care algorithm for the out-patients to guarantee their permanent and direct hospital access. We designed a specific section of the ICU as well as of the cardiac surgery ward to house the LVAD patients, independently of their reason for admission. Furthermore, LVAD patients undergoing any non-cardiac surgical interventions had to be attended by a cardiac anesthesiologist as well as by a perfusionist.

The LVAD coordinator was responsible for planning the monthly LVAD meeting assembling all core-actors. During this meeting, we also evaluated new candidates with terminal heart failure referred by external general practitioners and cardiologists. Urgent patients were discussed in extraordinary meetings.

Retrospective analysis

We reported common adverse events occurring after LVAD implantation as defined by the Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) [12]. To visualize time-to-event outcomes, we used the Kaplan-Meier estimator. We defined as primary outcomes: overall survival, freedom from stroke excluding TIA and minor stroke (i.e., with non-disabling neurologic deficit), freedom from device infection including driveline exit site infection, freedom from gastro-intestinal bleeding (GIB), and freedom from readmission due to LVAD- or cardiac related complications. We defined as first major adverse event after LVAD implantation the first occurrence of one the following: device infection, clinically significant bleeding (defined as requiring hospitalization for transfusion, endoscopy, or surgical intervention), device malfunction (defined as pump thrombosis or any dysfunction requiring LVAD explantation), stroke, or death. To investigate the evolution of dyspnea 3 months after implantation, we used a symmetry test on repeated NYHA assessments.

We described continuous variables as mean ± standard error or median (range minimum – maximum), categorical variables as number with percentage, survivals as percentage with 95% confidence intervals (CI). We carried out the statistical analysis using SPSS Statistics 24 (IBM, Armonk, NY, USA) and Stata 15 (Stata Corp., College Station, TX, USA). We compared our results to internationally reported data. This study was registered on the ClinicalTrials.gov database (NCT04263012).

Results

Perioperative patient characteristics

Between October 2014 and September 2019, 16 patients received an LVAD in our center. Most of the patients were male with a mean age at implantation of 67.1 years ±2.6. The mean preoperative EuroSCORE II was 24.4% ± 3.9 and the median INTERMACS level was 4 (range 1–5). Thirteen patients received an LVAD as DT and three patients as bridge-to-candidacy. The most frequent etiology of heart failure was ischemic, the remaining consisting of idiopathic dilated and valvular cardiomyopathies. Patients with prior cardiac surgery accounted for 37.5%. A concomitant operative procedure was performed in 75% of the patients including tricuspid valve repair, coronary artery bypass graft, mitral valve repair, and others. We implanted all LVAD in an on-pump, beating heart fashion with a mean cardiopulmonary bypass time of 139 min ± 10. Tricuspid valve repair was also performed beating heart. Aortic cross-clamp was limited to additional procedures on the left heart. Thirteen patients received HeartWare HVAD and three patients received HeartMate 3. The clinical follow-up ended on December 31, 2019. Table 1 details the patients ’demographics and perioperative characteristics.

Table 1 Patients’ demographics and perioperative characteristics

Overall survival and freedom from major adverse events

All patients survived the operation as well as their hospital course and rehabilitation stay. We observed a single case of severe right heart failure during the immediate postoperative course. Short-term right ventricle support with provisory implantation of an Impella RP® (ABIOMED Inc., Danvers, MA, USA) successfully restored the right ventricle function. We discharged the patients from the ICU after a median stay of 9.5 days (range 3–41). Five patients required early surgical re-exploration due to bleeding. We observed mostly diffuse bleeding. No surgical revision of the anastomosis or of the core-site was required.

During follow-up, 7 patients died after a mean time of 22 months ±5.2, including 5 from cardiac or LVAD-related conditions: multiple organ failure (n = 1), renal failure (n = 1), hemorrhagic shock secondary to systemic infection (n = 1), and neurological complications (n = 2). Among the deceased patients, 5 had been implanted as DT and 2 as bridge-to-candidacy. According to the Kaplan-Meier estimate, overall survival was 87.5% (CI 58.6–96.7), 70% (CI 37.5–87.8), and 49% (CI 18–74.3) at 1, 2, and 3 years, respectively (Fig. 1). Pump thrombosis occurred in 6 patients after a mean time of 16.8 months ±6. Pump thrombosis was diagnosed based on elevated LDH levels (at least twice the upper limit of normal) and sudden, sustained pump power elevation (> 1 W). All were treated successfully with systemic lysis therapy without further complication. No intracranial hemorrhage resulted from thombolytics. One patient required multiple lysis over several months due to recurrent / persistent thrombosis. The adjunction of clopidogrel to aspirin and vitamine K antagonist was finally successful in treating the thrombosis. No pump explantation was required due to thrombosis. We did not observe any other dysfunction of both devices. Stroke occurred in 3 patients, including hemorrhagic and ischemic insults. According to the Kaplan-Meier estimate, freedom from stroke was 81.3% (CI 52.5–93.5) at 1 and 2 years (Fig. 2). Furthermore, 5 patients experienced transient ischemic attacks or minor strokes with complete regression of symptoms within a few hours in all cases. Device infection occurred in 6 patients, including infections limited to the driveline exit site (n = 3) and systemic infection (n = 3) requiring long-term antibiotic therapy. Two cases of driveline infection required surgical debridement. According to the Kaplan-Meier estimate, freedom from device infection was 67.7% (CI 37.7–84.9) and 58.7% (CI 29.4–79.2) at 1 and 2 years, respectively (Fig. 3). No pump explantation was required due to infection. GIB occurred in 6 patients. According to Kaplan-Meier estimate, freedom from GIB was 75% (CI 46.3–89.8) and 56.3% (CI 26.0–78.2) at 1 and 2 years, respectively (Fig. 4). After discharge, all patients were eventually readmitted due to cardiac- or LVAD-related complications. The mean time to readmission was 8.6 months ±2.1. According to the Kaplan-Meier estimate, freedom from readmission was 50% (CI 25.5–74.5) and 31.3% (CI 8.6–54) and at 6 months and 1 year, respectively. Table 2 summarizes the postoperative follow-up and adverse events.

Fig. 1
figure 1

Overall survival after LVAD implantation

Fig. 2
figure 2

Freedom from stroke after LVAD implantation

Fig. 3
figure 3

Freedom from major infection after LVAD implantation

Fig. 4
figure 4

Freedom from gastrointestinal bleeding after LVAD implantation

Table 2 Postoperative follow-up and adverse events after LVAD implantation

Freedom from first major adverse event

Freedom from a first major adverse event was estimated at 50% (CI 24.5–71.1) and 43.8% (CI 19.8–65.6) at 6 months and 1 year, respectively.

Evolution of dyspnea

Based on NYHA assessment, dyspnea after 3 months was statistically significantly reduced according to the symmetry test (p = 0.04).

Comparison to internationally reported data

We compared the previous findings to international LVAD registries based on the following reports: the eighth annual INTERMACS, the European Registry for Patients with Mechanical Circulatory Support (EUROMACS) 2018, and the Society of Thoracic Surgeons (STS) 2019 [13,14,15]. Table 3 summarizes the comparison of our data to those internationally reported.

Table 3 Comparison of internationally reported overall survival and freedom from major adverse events after LVAD-Implantation

Comparing the INTERMACS cohort with specifically high INTERMACS scores (4–7), we reported a similar short-term overall survival (87.5% versus 84 and 70% versus 74% at 1 and 2 years, respectively). In terms of morbidity, we reported a lower short-term freedom from stroke (81.3% versus 86 and 81.3% versus 82% at 1 and 2 years, respectively), lower freedom from device infection (67.7% versus 86 and 58.7% versus 80% after 1 and 2 years, respectively), higher freedom from readmission (50% versus 39% after 6 months), and higher freedom from first major event (50% versus 45 and 43.8% versus 32% at 6 months and 1 year, respectively).

Compared to the EUROMACS cohort, we reported a higher overall survival (87.5% versus 69 and 70% versus 55% at 1 and 2 years, respectively).

Comparing the specific subgroup implanted with centrifugal-flow hybrid levitation devices (i.e. HVAD) of the STS cohort, we reported a higher short-term overall survival (87.5% versus 79 and 70% versus 69% at 1 and 2 years, respectively). We reported a comparable freedom from stroke (81.3 versus 84% und 81.3% versus 78% at 1 and 2 years, respectively), higher freedom from device infection (67.7% versus 57 and 58.7% versus 45% at 1 and 2 years, respectively), and lower freedom from GIB (freedom from GIB of 75% versus 80 and 56.3% versus 74% after 1 and 2 years, respectively).

Discussion

The increasing prevalence of advanced heart failure combined with population aging in western countries and limited availability of donor organs, account for the growing interest for LVAD as DT in the recent years. By depicting the set-up of our program, we sought to provide practical elements for similar-sized centers wishing to implement a mechanical-circulatory-support program for DT. To our knowledge, only a few center’s experience of establishing an LVAD-program are available with long-term results in the literature, and none specifically for DT [16,17,18,19,20,21]. Those available with long-term results usually concerned older-generation devices with different implantation strategies from those in our study (i.e. mainly bridge-to-transplant). Therefore, and to more objectively assess the outcomes of our cohort, we instead compared them to international LVAD registries, selecting, where appropriate, the subgroups whose profile better matched our cohort.

Overall survival

When comparing the INTERMACS cohort with specifically high INTERMACS profile patients (4–7), we observed an equivalent overall short-term survival. In the longer term, our patients’ survival was slightly lower. Nonetheless, this finding must be nuanced by the composition of the INTERMACS cohort, which includes patients with both strategies of DT and bridge-to-transplant (7389 versus 4761 for DT and bridge-to-transplant, respectively for the whole INTERMACS cohort). For DT patients are known for higher mortality, we may have expected a lower survival in our patients.

We interpreted the higher overall survival compared to EUROMACS due to the disparity of INTERMACS profiles between the cohorts (12.5% versus 69% of INTERMACS < 4 in the USB and EUROMACS cohort, respectively).

The STS 2019 report details the clinical outcomes of 3 different cohorts defined by the type of implanted devices: axial flow, centrifugal-flow with hybrid levitation, and centrifugal-flow with fully magnetic levitation. HeartWare HVAD corresponds to the second category. As our patients were mostly implanted with HeartWare HVAD, we chose to refer to this cohort. As with EUROMACS, the higher short-term survival of our patients was explainable by the disparity of INTERMACS profiles between the cohorts (12.5% versus 89.1% of INTERMACS < 4 in the USB and STS cohort, respectively).

Major adverse events

All strokes occurred during the first 6 months, explaining the relatively high short-term incidence of strokes. In the longer term, freedom from strokes was similar to that internationally reported. The overall high rate of neurologic events in this study may be explained by the device initially chosen, as HeartWare HVAD has been associated with higher rates of strokes compared both to HeartMate II and HeartMate 3 [22, 23]. The latter were predominantly implemented in the three mentioned international LVAD registries.

We observed a comparable freedom from infection to that of the STS registry but a notably lower to that of the INTERMACS registry. The literature mentions up to 51.9% infections after implantation of continuous-flow LVADs [24]. A recent review mentions 19–39% infection rates after implantation of second- and third-generation LVADs [25]. A Swiss group recently reported 45% LVAD-related infection after HeartMate 3 implantation, including driveline ex-site infections [26]. The latter rates correspond to our results (37.6%). 50% of the device-related infections in our cohort were limited to the driveline ex-site. Currently, risk factors for LVAD post-implantation infections have not been clearly identified. However, DT has been associated with increased susceptibility for device infection [24].

We reported a high occurrence of GIB. GIB is a common complication occurring in up to 61% of patients after LVAD implantation, presumably due to the combination of angiodysplasia formation and acquired von Willebrand syndrome resulting from the continuous-flow mechanical circulation [27]. Although controversial, evidence suggests that the risk of bleeding associated with angiodysplasia after LVAD implantation increases with age [28]. Angiodysplasia is sometimes a difficult diagnose that can be missed by endoscopy [29]. Out of 6 cases of GI-Bleeding in our cohort, 1 was due to angiodysplasia, 1 to gastric ulcer, 1 to colon ulcer, 1 to radiation proctitis, and 2 remained of unknown origin despite comprehensive work-up including upper, lower, and capsule endoscopy. All patients with GIB were implanted as DT with a mean age of 69.7 years. This finding suggests that the advanced age of our patients may have contributed to the high incidence of GIB, presumably due to undiagnosed angiodysplasia. The introduction of octreotide drastically reduced the recurrence of bleeding in our patients with diagnosed angiodysplasia or for whom the bleeding site could not be identified with endoscopy.

Study limitations

This study was limited by the small number of patients. Finding comparable data in the literature to critically assess the outcomes of our cohort was difficult. Indeed, the cohort was composed of highly selected patients (median INTERMACS score 4), mainly implanted as DT, and mainly with a single device (HeartWare HVAD). The number of patients was obviously too small to be statistically compared to cohorts such as those of INTERMACS, STS or EUROMACS. Thus, we mentioned the results of these registries as a reference and estimated the “trend” (higher, equivalent, or lower) between our results and those from the reports mentioned. We compared survivals from the INTERMACS registry specific for patients with high INTERMACS profile, since these better matched our cohort. For the same reason, we compared survivals from the STS registry specific for patients after implantation of centrifugal-flow hybrid levitation devices (i.e. HeartWare HVAD).

Our cohort consisted mostly of “frequent flyers” (INTERMACS profile 4), for we did not intend to primarily implant LVADs in inotrope-dependent, instable patients while starting the program. However, the high EuroSCORE II (24.4%) underlined the high morbidity of the included patients.

Finally, we did not specifically attest the patients’ quality of life of with a questionnaire. Nevertheless, the statistically significant reduction of dyspnea 3 months after LVAD implantation highlighted the subjective improvement of the patients’ condition.

Conclusions

The Basel experience demonstrated the possible implementation of an LVAD program for DT or bridge-to-candidacy in a non-transplant CHFC with midterm survival results and freedom from major adverse events comparable to international registries. This study was designed to detail practical, useful aspects for centers wishing to develop a mechanical-circulatory-support program for DT. Our findings are encouraging for similar-sized centers, for they somewhat contradicted previously reported data suggesting that low center volume negatively impacts clinical outcomes after LVAD implantation [30]. Patient selection remains crucial.

Availability of data and materials

The datasets used and/or analyzed during the current study are available from the corresponding author on reasonable request.

Abbreviations

HTx:

Heart transplant

LVAD:

Left-ventricular assist device

DT:

Destination therapy

USB:

University Hospital of Basel

CHFC:

Comprehensive heart-failure center

ICU:

Intensive care unit

RV:

Right ventricle

INTERMACS:

Interagency Registry for Mechanically Assisted Circulatory Support

GIB:

Gastrointestinal bleeding

References

  1. Farrar DJ, Hill JD. Univentricular and biventricular thoratec VAD support as a bridge to transplantation. Ann Thorac Surg. 1993;55(1):276–82. https://doi.org/10.1016/0003-4975(93)90537-R.

    Article  CAS  PubMed  Google Scholar 

  2. Rose EA, Gelijns AC, Moskowitz AJ, Heitjan DF, Stevenson LW, Dembitsky W, et al. Long-term use of a left ventricular assist device. N Engl J Med. 2001;345(20):1435–43. https://doi.org/10.1056/NEJMoa012175.

    Article  CAS  PubMed  Google Scholar 

  3. Peura JL, Colvin-Adams M, Francis GS, Grady KL, Hoffman TM, Jessup M, et al. Recommendations for the use of mechanical circulatory support: device strategies and patient selection: a scientific statement from the American heart association. Circulation. 2012;126(22):2648–67. https://doi.org/10.1161/CIR.0b013e3182769a54.

    Article  PubMed  Google Scholar 

  4. Weiss J, Beyeler F, Immer FF. Heart allocation and transplantation in Switzerland since the introduction of the Swiss Organ Allocation System (SOAS). Swiss Med Wkly. 2014;144(November):1–9. https://doi.org/10.4414/smw.2014.14057.

    Article  Google Scholar 

  5. Aaronson KD, Slaughter MS, Miller LW, McGee EC, Cotts WG, Acker MA, et al. Use of an intrapericardial, continuous-flow, centrifugal pump in patients awaiting heart transplantation. Circulation. 2012;125(25):3191–200. https://doi.org/10.1161/CIRCULATIONAHA.111.058412.

    Article  PubMed  Google Scholar 

  6. Mehra MR, Goldstein DJ, Uriel N, Cleveland JC Jr, Yuzefpolskaya M, Salerno C, et al. Two-year outcomes with a magnetically levitated cardiac pump in heart failure. N Engl J Med. 2018;378(15):1386–95. https://doi.org/10.1056/NEJMoa1800866.

    Article  PubMed  Google Scholar 

  7. Ponikowski P, et al. 2016 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure. Eur Heart J. 2016;37(27):2129–2200m. https://doi.org/10.1093/eurheartj/ehw128.

    Article  PubMed  Google Scholar 

  8. Gustafsson F, Rogers JG. Left ventricular assist device therapy in advanced heart failure: patient selection and outcomes. Eur J Heart Fail. 2017;19(5):595–602. https://doi.org/10.1002/ejhf.779.

    Article  PubMed  Google Scholar 

  9. Matthews JC, Koelling TM, Pagani FD, Aaronson KD. The right ventricular failure risk score. A pre-operative tool for assessing the risk of right ventricular failure in left ventricular assist device candidates. J Am Coll Cardiol. 2008;51(22):2163–72. https://doi.org/10.1016/j.jacc.2008.03.009.

    Article  PubMed  PubMed Central  Google Scholar 

  10. Atluri P, et al. Predicting right ventricular failure in the modern, continuous flow left ventricular assist device era. Ann Thorac Surg. 2014;96(3):857–64. https://doi.org/10.1016/j.athoracsur.2013.03.099.Predicting.

    Article  Google Scholar 

  11. Teuteberg JJ, Slaughter MS, Rogers JG, McGee EC, Pagani FD, Gordon R, et al. The HVAD left ventricular assist device: risk factors for neurological events and risk mitigation strategies. JACC Heart Fail. 2015;3(10):818–28. https://doi.org/10.1016/j.jchf.2015.05.011.

    Article  PubMed  Google Scholar 

  12. STS INTERMACS Database, INTERMACS Adverse Event Definitions: Adult and Pediatric patients, 2016. Available: https://www.uab.edu/medicine/intermacs/images/protocol-5-appendices/Appendix_A_INTERMACS_AE_Definitions_Final_02-4-2016.docx.

    Google Scholar 

  13. Kirklin JK, Pagani FD, Kormos RL, Stevenson LW, Blume ED, Myers SL, et al. Eighth annual INTERMACS report: special focus on framing the impact of adverse events. J Heart Lung Transplant. 2017;36(10):1080–6. https://doi.org/10.1016/j.healun.2017.07.005.

    Article  PubMed  Google Scholar 

  14. de By TMMH, Mohacsi P, Gahl B, Zittermann A, Krabatsch T, Gustafsson F, et al. The European registry for patients with mechanical circulatory support (EUROMACS) of the European Association for Cardio-Thoracic Surgery (EACTS): second report. Eur J Cardiothorac Surg. 2018;53(2):309–16. https://doi.org/10.1093/ejcts/ezx320.

    Article  PubMed  Google Scholar 

  15. Teuteberg JJ, Cleveland JC Jr, Cowger J, Higgins RS, Goldstein DJ, Keebler M, et al. The Society of Thoracic Surgeons Intermacs 2019 annual report: the changing landscape of devices and indications. Ann Thorac Surg. 2020;109(3):649–60. https://doi.org/10.1016/j.athoracsur.2019.12.005.

    Article  PubMed  Google Scholar 

  16. Lim CP, Sivathasan C, Tan TE, Lim CH, Kerk KL, Sim DKL. Use of left ventricular assist device (HeartMate II): a Singapore experience. Artif Organs. 2014;38(7):543–8. https://doi.org/10.1111/aor.12247.

    Article  PubMed  Google Scholar 

  17. Pya Y, Bekbossynova M, Jetybayeva S, Bekbossynov S, Andossova S, Salov R, et al. Initial 3-year outcomes with left ventricular assist devices in a country with a nascent heart transplantation program. ESC Heart Fail. 2016;3(1):26–34. https://doi.org/10.1002/ehf2.12066.

    Article  PubMed  Google Scholar 

  18. Nestorovic E, et al. Successful establishment of a left ventricular assist device program in an emerging country: One year experience. J Thorac Dis. 2018;10(Suppl 15):S1743–50. https://doi.org/10.21037/jtd.2018.04.147.

    Article  PubMed  PubMed Central  Google Scholar 

  19. Pedemonte O, et al. Left ventricular assist device (LVAD) program in Chile: First successful experience in South America. J Thorac Dis. 2018;10(Suppl 15):S1751–7. https://doi.org/10.21037/jtd.2018.02.83.

    Article  PubMed  PubMed Central  Google Scholar 

  20. Tarazi R, et al. Left ventricular assist device therapy: The Kuwait experience. J Thorac Dis. 2018;10(Suppl 15):S1758–62. https://doi.org/10.21037/jtd.2017.12.54.

    Article  PubMed  PubMed Central  Google Scholar 

  21. Haeck MLA, Beeres SLMA, Höke U, Palmen M, Couperus LE, Delgado V, et al. Left ventricular assist device for end-stage heart failure: results of the first LVAD destination program in the Netherlands. Neth Heart J. 2015;23(2):102–8. https://doi.org/10.1007/s12471-014-0602-4.

    Article  CAS  PubMed  Google Scholar 

  22. Rogers JG, Pagani FD, Tatooles AJ, Bhat G, Slaughter MS, Birks EJ, et al. Intrapericardial left ventricular assist device for advanced heart failure. N Engl J Med. 2017;376(5):451–60. https://doi.org/10.1056/nejmoa1602954.

    Article  PubMed  Google Scholar 

  23. Chiang YP, Cox D, Schroder JN, Daneshmand MA, Blue LJ, Patel CB, et al. Stroke risk following implantation of current generation centrifugal flow left ventricular assist devices. J Card Surg. 2020;35(2):383–9. https://doi.org/10.1111/jocs.14397.

    Article  PubMed  Google Scholar 

  24. Topkara VK, Kondareddy S, Malik F, Wang IW, Mann DL, Ewald GA, et al. Infectious complications in patients with left ventricular assist device: etiology and outcomes in the continuous-flow era. Ann Thorac Surg. 2010;90(4):1270–7. https://doi.org/10.1016/j.athoracsur.2010.04.093.

    Article  PubMed  Google Scholar 

  25. Zinoviev R, Lippincott CK, Keller SC, Gilotra NA. In Full Flow: Left Ventricular Assist Device Infections in the Modern Era. Open Forum Infect Dis. 2020;7(5). https://doi.org/10.1093/ofid/ofaa124.

  26. Nowacka A, Hullin R, Tozzi P, Barras N, Regamey J, Yerly P, et al. Short-term single-Centre experience with the HeartMate 3 left ventricular assist device for advanced heart failure. Eur J Cardiothorac Surg. 2020;58(3):511–8. https://doi.org/10.1093/ejcts/ezaa075.

    Article  PubMed  Google Scholar 

  27. Kataria R, Jorde UP. Gastrointestinal bleeding during continuous-flow left ventricular assist device support state of the field. Cardiol Rev. 2019;27(1):8–13. https://doi.org/10.1097/CRD.0000000000000212.

    Article  PubMed  Google Scholar 

  28. Demirozu ZT, Radovancevic R, Hochman LF, Gregoric ID, Letsou GV, Kar B, et al. Arteriovenous malformation and gastrointestinal bleeding in patients with the HeartMate II left ventricular assist device. J Heart Lung Transplant. 2011;30(8):849–53. https://doi.org/10.1016/j.healun.2011.03.008.

    Article  PubMed  Google Scholar 

  29. Richter JM, Hedberg SE, Athanasoulis CA, Schapiro RH. Angiodysplasia - Clinical presentation and colonoscopic diagnosis. Dig Dis Sci. 1984;29(6):481–5. https://doi.org/10.1007/BF01296266.

    Article  CAS  PubMed  Google Scholar 

  30. Lietz K, Long JW, Kfoury AG, Slaughter MS, Silver MA, Milano CA, et al. Impact of center volume on outcomes of left ventricular assist device implantation as destination therapy analysis of the thoratec heartmate registry, 1998 to 2005. Circ Heart Fail. 2009;2(1):3–10. https://doi.org/10.1161/CIRCHEARTFAILURE.108.796128.

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

The authors acknowledge the nurses from at the cardiac surgery ward, the ICU nurses as well as the palliative care team of the University Hospital of Basel. We also acknowledge all collaborators involved in the implementation of this program and in the care of our patients.

Funding

The authors received no financial support for the research, authorship, and/or publication of this study.

Author information

Authors and Affiliations

Authors

Contributions

TS and MG wrote the manuscript; OP and FE were major contributors to the conception of the study and revised the manuscript; TS and CM collected the data; PM, FR, SS, AM, UZ, TD, JE, JF, NC, MS, HP, and SO contributed to the conception of the study; BG corrected the statistical analysis. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Martin Grapow.

Ethics declarations

Ethics approval and consent to participate

The regional ethics committee Ethikkommission Nordwest- und Zentralschweiz validated the project (ID 2020–00017). Patients implanted with LVAD who specifically refused their data use for research purposes were excluded from the study (n = 1).

Consent for publication

Written informed consent for publication was obtained from all patients involved in this study.

Competing interests

The authors declare no competing interest.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Schaeffer, T., Pfister, O., Mork, C. et al. 5-year results of a newly implemented mechanical circulatory support program for terminal heart failure patients in a Swiss non-cardiac transplant university hospital. J Cardiothorac Surg 16, 64 (2021). https://doi.org/10.1186/s13019-021-01447-5

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13019-021-01447-5

Keywords