Multicenter randomized controlled trial comparing digital and traditional chest drain in a VATS pulmonary lobectomy cohort: interim analysis

Abstract

Background

The usefulness of digital chest drain is still debated. We are carrying out a study to determine if the use of a digital system compared with a traditional system reduces the duration of chest drainage. To evaluate safety, benefit, or futility of this trial we planned the current interim analysis.

Methods

An interim analysis on preliminary data from ongoing investigator-initiated, multicenter, interventional, prospective randomized trial. Original protocol number: (NCT03536130). The interim main endpoint was overall complications; secondary endpoints were the concordance between the two primary endpoints of the RCT (chest tube duration and length of hospital stay). We planned the interim analysis when half of the patients have been randomised and completed the study. Data were described using mean and standard deviation or absolute frequencies and percentage. T-test for unpaired samples, Chi-square test, Poisson regression and absolute standardized mean difference (ASMD) were used. P-value < 0.05 was considered significant.

Results

From April 2017 to November 2018, out of 317 patients enrolled by 3 centers, 231 fulfilled inclusion criteria and were randomized. Twenty-two of them dropped out after randomization. Finally, 209 patients were analyzed: among them 94 used the digital device and 115 the traditional one. The overall postoperative complications were 35 (16.8%) including prolonged air leak (1.9%). Mean chest tube duration was 3.6 days (SD = 1.8), with no differences between two groups (p = 0.203). The overall difference between hospital stay and chest tube duration was 1.4 days (SD = 1.4). Air leak at first postoperative day detected by digital and traditional devices predicted increasing in tube duration of 1.6 day (CI 95% 0.8–2.5, p < 0.001) and 2.0 days (CI 95% 1.0–3.1, p < 0.001), respectively.

Conclusions

This interim analysis supported the authors’ will to continue with the enrollment and to analyze data once the estimated sample size will be reached.

Trial registration

Trial registration number NCT03536130, Registered 24 May 2018 - Retrospectively registered.

Peer Review reports

Background

Air leaks are common after pulmonary resection, affecting patients with a prevalence ranging from 3 to 33%, and are associated with increased morbidity, prolonged hospital stay and increased costs [1, 2].

Conventionally, assessment of air leaks relied on the measurement of “bubbles in a chamber” by using traditional chest drainage systems. In recent years, novel digital devices have been introduced; it is believed that these devices have specific advantages. Digital drainages provide a continuous and objective assessment of air leaks, minimizing interobserver variability [3], thus reducing the need for tube clamping trials and finally optimizing the timing of chest tube removal. Moreover, these modern systems could be able to distinguish an active air leak from pleural space effect by evaluating the differential intrapleural pressure [4]. Finally, digital devices could help identify patients at high risk for prolonged air leak, allowing a better patient management in terms of either active intervention or early discharge from the hospital with a one-way valve system [5, 6].

Few studies, either retrospective or randomized controlled trials (RCT), comparing digital and analog chest drainage systems have been published, and results are conflicting regarding the advantages of one system over the other. In particular, it is not clear yet if the novel systems could actually lead to optimization of chest tube management in terms of chest tube duration and therefore length of hospital stay [7,8,9].

Considering that additional evidence is needed to further probe the potential clinical utility and impact of digital chest drainage devices, we implemented a randomized controlled trial; the title was “Comparison Between Electronic and Traditional Chest Drainage Systems” (NCT 03536130). This trial started in 2017; recruitment will finish by the end of 2020.

To evaluate safety, benefit, or futility of this RCT we planned the current interim analysis.

Methods

This is the interim analysis on preliminary data from ongoing investigator-initiated, multicenter, interventional, prospective randomized trial. The interim main endpoint was overall complications within 30 days of the surgery; secondary endpoints were the concordance between the two primary endpoints of the RCT (chest tube duration and length of hospital stay).

The RCT protocol was published online (clinicaltrials.gov/ct2/show/study/NCT03536130. Briefly, three different staff surgeons from three Italian high-volume thoracic surgery units enrolled all adult patients scheduled for video assisted thoracic surgery (VATS) lobectomy for both malignant and benign disease. All patients signed and dated an Italian-written informed consent form approved from ethical committees of the three hospitals. Individual randomization, stratified by centers, was performed with a 1:1 allocation to the intervention (Digital group) and control groups (Traditional group); the nature of the intervention did not allow blind randomization. At the end of surgery, a 28 Ch chest tube was connected to a digital device (Drentech™ Palm Evo system - Redax, Fig. 1) or traditional water-seal drain system. Chest tube was removed when chest X-rays show a complete lung expansion and there was no detectable air leak on traditional devices or when airflow is lower than 20 ml/min for at least 8 h on digital ones. In addition, daily fluid drainage should be less than 300 ml. When air leaks exceed 7 days they are considered “prolonged”. The sample size of the RCT is 382 patients (191 per group); the calculation was based on the two co-primary outcomes: duration of chest drain and length of hospital stay. The trial protocol was previously published meticulously detailing the study procedure [10]. We planned the interim analysis when half of the patients have been randomised and completed the study.

Fig. 1
figure 1

Chest drainage connected to digital device (Drentech™ Palm Evo system - Redax)

In this interim analysis, safety was measured by complication rates; complications were defined according the Common Terminology Criteria for Adverse Events v4.03 and they were recorded when classified as grade 2 or greater. The concordance between co-primary outcomes was measured by difference between hospital stay and chest tube duration (days). Benefit and futility were estimated by comparing the duration of drainage between the two groups (days).

The study adheres to CONSORT guidelines, and a completed CONSORT checklist is available as Supplementary Material.

Statistical analysis

Data are presented as mean and standard deviation (SD). Categorical variables are shown as absolute frequencies and percentages. Student’s T and χ2 tests were performed as appropriate. The normality assumption was assessed by visual inspection of histogram and Q-Q plot. We used the absolute standardized mean difference (ASMD) to evaluate covariance balance between study groups; a value equal or less than 0.20 was considered as a small effect size. The Poisson regression was performed. The 95% Wald confidence intervals were computed. Two-sided p-value was considered statistically significant when < 0.05. All analyses were carried out using R version 3.2.2 software [11].

Results

Three-hundred and seventeen patients who potentially met the inclusion criteria underwent lung resection between April 2017 and November 2018. CONSORT flow diagram summarizes patients’ recruitment (Fig. 2); finally, 209 patients were included in the current interim analysis: 94 assigned to Digital group and 115 to Traditional group. Table 1 shows preoperative and intraoperative patients characteristics; the comparison of the two groups with the ASMD did not overstep the value of 0.20 for any of the characteristics showing a substantial balance of the covariates. The overall postoperative complications were 35 (16.8%) including prolonged air leak (1.9%); Table 2 shows the results distributed per group; none of the described complications could be correlated with the drainage devices. Mean chest tube duration was 3.6 days (SD = 1.8); there were no statistically significant differences between groups: difference of means was − 0.33 days (95% CI: − 0.83 to − 0.018; p = 0.203). The overall difference between hospital stay and chest tube duration was 1.4 days (SD = 1.4).

Fig. 2
figure 2

CONSORT Flow Diagram of the study

Table 1 Preoperative and intraoperative patients’ characteristics
Table 2 Postoperative events

The mean duration of chest tube drainage in patients with POD1 air leaks was 4.4 days (SD = 1.8 days) and 5.1 days (SD = 1.9 Days) in Digital group and Traditional group respectively (p = 0.175).

The mean duration of chest tube drainage in patients without POD1 air leaks was 2.8 days (SD = 1.3 days) and 3.3 days (SD = 1.4 days) in Digital and Traditional groups, respectively (p = 0.022).

Air leak at first postoperative day detected by digital and traditional device predicted increasing in tube duration of 1.6 day (CI 95% 0.8–2.5, p < 0.001) and 2.0 days (CI 95% 1.0–3.1, p < 0.001), respectively.

Discussion

The RCT “Comparison Between Electronic and Traditional Chest Drainage Systems” aims to identify the possible benefit of electronic drainage for managing patients who underwent VATS lobectomy. We regarded Data and Safety Monitoring Committee as unnecessary, considering that the device is commercially available and the device was approved by the Ministry of Health; nevertheless, we planned the interim analysis to assess safety, benefit or futility.

This RCT had a dropout rate of 9.5%, which was close to the median percentage of patients with a missing outcome from RCTs published in 4 top medical journals recently reviewed [12]. We considered the missing data as “missing completely at random”; we are aware that this is a strong assumption but, on the other hand, the intention-to-treat principle was impossible to apply due to the very nature of this RCT. We have not recorded any unfavorable events directly attributable to the drainage devices, whether they are digital or not. Postoperative complications were similar between the two groups and not directly related to the type of device. We can affirm that the study protocol did not cause any harm to the enrolled patients and therefore proved to be safe.

The difference between the two groups in terms of chest tube duration was not statistically significant, thus the study cannot be stopped for benefit. However, a trend toward shorter chest tube duration and length of stay was observed in the Digital group; as a consequence, we consider it cost-effective and justified to continue the study to determine if this trend will reach statistical significance.

Finally, two additional items worth some comments: the primary objective and a predictive factor for prolonged air leak. Our RCT has a primary composite objective, therefore we wanted to check that the two parameters (duration of chest tube drainage and length of hospital stay) were actually correlated; we assumed that the difference between the two parameters should remain within 2 days. Indeed, the data collected in this interim analysis showed that the two parameters remained closely related and consequently a re-modulation of the study protocol will not be necessary. Despite this study was not planned to identify prognostic factors for air leak, we observed that the presence of air leakage on the first postoperative day predicted the prolonged chest tube requirement as reported by others [13].

Conclusions

In conclusion, this interim analysis supported the authors’ will to continue with the enrollment and to analyze data once the estimated sample size will be reached.

Availability of data and materials

The datasets generated and analyzed during the current study are available from the corresponding author on reasonable request.

Abbreviations

ASMD:

Absolute standardized mean difference

CI:

Confidence interval

RCT:

Randomized controlled trial

SD:

Standard deviation

VATS:

Video assisted thoracic surgery

References

  1. Lackey A, Mitchell JD. The cost of air leak: physicians' and patients' perspectives. Thorac Surg Clin. 2010;20(3):407–11. https://doi.org/10.1016/j.thorsurg.2010.04.004.

    Article  PubMed  Google Scholar 

  2. Li S, Lv W, Zhou K, Che G. Does the fissureless technique decrease the incidence of prolonged air leak after pulmonary lobectomy? Interact Cardiovasc Thorac Surg. 2017;25(1):122–4. https://doi.org/10.1093/icvts/ivx061.

    Article  PubMed  Google Scholar 

  3. Cerfolio JR, Varela G, Brunelli A. Digital and smart chest drainage systems to monitor air leaks: the birth of a new era? Thorac Surg Clin. 2010;20(3):413–20. https://doi.org/10.1016/j.thorsurg.2010.03.007.

    Article  PubMed  Google Scholar 

  4. Marasco RD, Giudice G, Lequaglie C. How to distinguish an active air leak from a pleural space effect. Asian Cardiovasc Thorac Ann. 2012;20(6):682–8. https://doi.org/10.1177/0218492312451918.

    Article  PubMed  Google Scholar 

  5. Brunelli A, Salati M, Refai M, Di Nunzio L, Xiumé F, Sabbatini A. Evaluation of a new chest tube removal protocol using digital air leak monitoring after lobectomy: a prospective randomised trial. Eur J Cardiothorac Surg. 2010;37(1):56–60. https://doi.org/10.1016/j.ejcts.2009.05.006.

    Article  PubMed  Google Scholar 

  6. Takamochi K, Imashimizu K, Fukui M, Maeyashiki T, Suzuki M, Ueda T, et al. Utility of objective chest tube management after pulmonary resection using a digital drainage system. Ann Thorac Surg. 2017;104(1):275–83. https://doi.org/10.1016/j.athoracsur.2017.01.061.

    Article  PubMed  Google Scholar 

  7. Wang H, Hu W, Ma L, Zhang Y. Digital chest drainage system versus traditional chest drainage system after pulmonary resection: a systematic review and meta-analysis. J Cardiothorac Surg. 2019;14(1):13. https://doi.org/10.1186/s13019-019-0842-x.

    Article  PubMed  PubMed Central  Google Scholar 

  8. Plourde M, Jad A, Dorn P, Harris K, Mujoomdar A, Henteleff H, et al. Digital air leak monitoring for lung resection patients: a randomized controlled clinical trial. Ann Thorac Surg. 2018;106(6):1628–32. https://doi.org/10.1016/j.athoracsur.2018.06.080.

    Article  PubMed  Google Scholar 

  9. Lijkendijk M, Licht PB, Neckelmann K. Electronic versus traditional chest tube drainage following lobectomy: a randomized trial. Eur J Cardiothorac Surg. 2015;48(6):893–8. https://doi.org/10.1093/ejcts/ezu535.

    Article  PubMed  Google Scholar 

  10. Marulli G, Comacchio GM, Nosotti M, Rosso L, Mendogni P, Natale G, et al. Multicenter randomized study on the comparison between electronic and traditional chest drainage systems. Trials. 2019;20(1):730.

    Article  Google Scholar 

  11. Core Team R. R: a language and environment for statistical computing. Vienna: R Foundation for StatisticalComputing; 2019. https://www.R-project.org/. Accessed 2 Mar 2020

    Google Scholar 

  12. Bell ML, Fiero M, Horton NJ, Hsu CH. Handling missing data in RCTs; a review of the top medical journals. BMC Med Res Methodol. 2014;14(1):118. https://doi.org/10.1186/1471-2288-14-118.

    Article  PubMed  PubMed Central  Google Scholar 

  13. Rodríguez M, Jiménez MF, Hernández MT, Novoa NM, Aranda JL, Varela G. Usefulness of conventional pleural drainage systems to predict the occurrence of prolonged air leak after anatomical pulmonary resection. Eur J Cardiothorac Surg. 2015;48(4):612–5. https://doi.org/10.1093/ejcts/ezu470.

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

Not applicable.

Funding

No specific funding for the project was received.

Author information

Authors and Affiliations

Authors

Contributions

PM and DT have the idea, wrote and designed the study. MN, GM and FR designed the study. GMC, SP, VR, GI, DB, LGA collected and assembled the patient data; GB made the statistical analysis. CL contributed in writing of the manuscript. All authors read and approved the manuscript.

Corresponding author

Correspondence to Paolo Mendogni.

Ethics declarations

Ethics approval and consent to participate

The study has been approved by the Ethics Board of Fondazione IRCCS Ca′ Granda Ospedale Maggiore Policlinico, Milan, Italy (reference number 400_2017bis).

All participants receive brief and comprehensible oral and written information, in accordance with the Helsinki Declaration. Before commencing screening and outcome assessment, all procedures are explained by the assessor and the informed consent form is reviewed and signed.

Consent for publication

Not applicable.

Competing interests

All authors declare that they have no competing interest to declare.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary Information

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Mendogni, P., Tosi, D., Marulli, G. et al. Multicenter randomized controlled trial comparing digital and traditional chest drain in a VATS pulmonary lobectomy cohort: interim analysis. J Cardiothorac Surg 16, 188 (2021). https://doi.org/10.1186/s13019-021-01567-y

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13019-021-01567-y

Keywords