- Case Report
- Open access
- Published:
Endoscopic-assisted descending aortic replacement through a small intercostal incision: a case report
Journal of Cardiothoracic Surgery volume 17, Article number: 305 (2022)
Abstract
Background
Descending aortic replacement often involves making large incisions; thus, it results in massive invasions. We report the case of a patient with dilated descending aorta treated using endoscopic-assisted descending aortic replacement with essentially minimal invasions.
Case presentation
We performed endoscopic-assisted descending aortic replacement with a single incision involving six wounds by trocar puncturing on a 59-year-old man who was diagnosed with dilated descending aorta by stent graft-induced new entry. Subsequently, the patient was discharged on postoperative day 11 without any complications.
Conclusions
Despite minor incisions, our approach can be indicated to almost the same group of patients in whom the conventional approach can be performed. Our procedure involved a single incision of only 8 cm and six wounds by trocar puncturing. Thus, endoscopic-assisted surgery can be a useful option in descending aortic surgery.
Background
The application of endoscopic surgery is rapidly being established and expanded in cardiac surgery. However, the use of endoscopes in aortic surgeries remains limited. In this report, we present a case that involved the performance of endoscopic-assisted descending aortic replacement with a single incision of only 8 cm and six wounds by trocar puncturing. We consider it an important option for aortic surgeries to properly use endoscopes in this minimally invasive era.
Case presentation
A 59-year-old man was admitted to our hospital for progressive dilatation of the descending aorta. Anamnesis revealed no drug use or family history for the condition. One year before admission, he was diagnosed with type B aortic dissection while during the same hospitalization period, he was later diagnosed with acute myocardial infarction. The primary tear was located in the distal aortic arch. Open stent-grafting to seal the primary entry and coronary artery bypass grafting were performed. Three months later, his abdominal aorta was replaced with a Y-shaped graft due to dilation of his abdominal aorta. Thereafter, he received computed tomography (CT) follow-up regularly. The diameter of the descending aorta decreased for the first six months; however, CT defined redilatation of the descending thoracic aorta one year after surgery. Contrast-enhanced CT revealed the presence of stent graft-induced new entry (SINE). The maximum minor-axis diameter of the descending thoracic aorta was 52 mm (Fig. 1). Transthoracic echocardiography revealed a reduced ejection fraction, 37.1%, and inferior-lateral hypokinesis. This patient had already undergone open stent-grafting and Y-shaped grafting. We deduced that this patient was at high risk of paraplegia after conservative descending aortic replacement. Thoracic endovascular aortic repair (TEVAR) was considered; however, there were further SINE risks due to the patient’s history of type B aortic dissection and other aortic diseases. Thus, we decided to perform the procedure via minimal thoracotomy with a 3D endoscope to allow as much collateral circulation as possible. Cerebrospinal fluid drainage was performed on the day before the operation. The patient was placed in a modified right lateral decubitus position and the 5th intercostal space was opened by 8 cm and one-lung ventilation was started. Trocars for the IMAGE 1 SPIES 3D endoscope system (Karl Storz, Tuttlingen, Germany) and instruments were inserted through the 5th, 6th, and 7th intercostal spaces. Proximal and distal aortic clamps were inserted through the 4th and 9th intercostal spaces, respectively. Furthermore, a suction line was inserted through the 8th intercostal space (Figs. 2, 3). The patient underwent mild (35 °C) hypothermic partial cardiopulmonary bypass with the left femoral artery perfusion along with drainage of the right jugular and femoral veins. The endoscope was inserted through the 7th intercostal space for the proximal side procedure, and the 5th intercostal space for the distal side procedure. Surgical instruments were inserted through the main incision and another port separate from the endoscopic port. While carefully separating the descending aorta and avoiding injuring the esophagus, the proximal and distal aorta were clamped. Opening the descending aortic aneurysm revealed the entry tear due to an open stent graft (Fig. 2A). After sealing three intercostal arterial orifices (Fig. 2B), we performed distal anastomosis by a continuous-suture graft-inclusion technique (Fig. 2C) with a 26 mm J Graft SHIELD NEO® (Japan Lifeline Co., Ltd., Tokyo, Japan) using 3–0 polypropylene sutures with a bovine pericardium strip. Traction sutures for the aortic wall were applied to avoid sewing the esophagus. Subsequently, we performed proximal anastomosis directly to the open stent graft (Fig. 2D) using 4–0 polypropylene sutures. A bovine pericardium strip was sewn to the inside of the open stent graft without aortic wall. The cardiopulmonary bypass time was 179 min. He was discharged on the postoperative day 11 without any complications.
Discussion
Even though minimally invasive cardiac surgery (MICS) spreads widely in the field of cardiac surgery, descending aortic replacement surgery still involves high invasiveness. The conventional approach requires making a large incision with transection of rib bones to gain a large surgical field. Since Dake et al. reported the first case of TEVAR for descending aortic aneurysm in 1994 [1], descending aortic treatment has changed in terms of low invasiveness in which it is no longer necessary to use one-lung ventilation or cardiopulmonary bypass. However, TEVAR is only advised to highly selective patients to whom it is anatomically feasible. Despite minor incisions, our approach can be indicated to almost the same group of patients in whom the conventional approach can be performed. In our case a single incision of only 8 cm and six wounds by trocar puncturing were performed.
There are several advantages associated with the use of an endoscope for aortic surgery. For instance, endoscopic surgery provides lower invasiveness and a clearer endoscopic view in a compatible way. Further, a 3D endoscope provides better depth perception and spatial orientation. In addition, smaller incisions result in lesser surgery-related blood loss and pain [2]. Consequently, patients are expected to stay for a shorter duration in the hospital. One limitation of endoscopic-assisted descending aortic surgery is the difficulty of reconstructing intercostal arteries. Intercostal arteries reconstruction and operative time are trade-offs; however, this problem is expected to solve as the surgeon performs a greater number of surgeries.
To minimize the risk of paraplegia after descending aortic surgery, various precautions have been taken [3,4,5,6]. As we have already reported that endoscopic-assisted aortic surgery might have reduced risk of spinal cord injury [7]. This is because preserving the intercostal arteries and multiple vessels surrounding the chest muscles is important to maintain the blood supply to the spinal cord [8]. Furthermore, large incisions can damage the intercostal arteries and multiple vessels running in the chest muscles. Our method may contribute towards maintaining the collateral blood network of the spinal cord and prevent paraplegia, especially in high-risk patients. Previously, we reported a similar case of endoscopic-assisted descending aortic replacement. However, that case was performed with an approximate incision of 30 cm while the incision in current case was only 8 cm. We believe that this reduction in the incision site from 30 to 8 cm will lead to totally endoscopic descending aortic surgery in the future.
Conclusion
We report a case of endoscopic-assisted minimally invasive descending aortic surgery. Based on the outcomes noted in our patient, endoscopic-assisted surgery can be a useful option in descending aortic surgery. Our method can be used toward the development of totally endoscopic descending aortic surgery in the future.
Availability of data and materials
The datasets of this article are available on reasonable request.
References
Dake MD, Miller DC, Semba CP, et al. Transluminal placement of endovascular stent-grafts for the treatment of descending thoracic aortic aneurysms. N Engl J Med. 1994;331:1729–34.
Svensson LG, Atik FA, Cosgrove DM, et al. Minimally invasive versus conventional mitral valve surgery: a propensity-matched comparison. J Thorac Cardiovasc Surg. 2010;139:926-32.e1. https://doi.org/10.1016/j.jtcvs.2009.09.038.
Coselli JS, LeMaire SA, Köksoy C, et al. Cerebrospinal fluid drainage reduces paraplegia after thoracoabdominal aortic aneurysm repair: Results of a randomized clinical trial. J Vasc Surg. 2002;35:631–9. https://doi.org/10.1067/mva.2002.122024.
Afifi RO, Sandhu HK, Zaidi ST, Trinh E, Tanaka A, Miller CC III, et al. Intercostal artery management in thoracoabdominal aortic surgery: to reattach or not to reattach? J Thorac Cardiovasc Surg. 2018;155:1372-8.e1. https://doi.org/10.1016/j.jtcvs.2017.11.072.
Acher CW, Wynn MM, Hoch JR, et al. Combined use of cerebral spinal fluid drainage and naloxone reduces the risk of paraplegia in thoracoabdominal aneurysm repair. J Vasc Surg. 1994;19:236–46. https://doi.org/10.1016/s0741-5214(94)70099-0.
Kouchoukos NT, Masetti P, Rokkas CK, et al. Hypothermic cardiopulmonary bypass and circulatory arrest for operations on the descending thoracic and thoracoabdominal aorta. Ann Thorac Surg. 2002;74:S1885–7. https://doi.org/10.1016/s0003-4975(02)04153-x.
Sako H, Tanaka H, Takayama T, Abe T, et al. Endoscopic-assisted aortic replacement of the descending aorta through the 8th intercostal space to preserve collateral vessels: a case report. Gen Thorac Cardiovasc Surg. 2020;68:1027–30. https://doi.org/10.1007/s11748-019-01198-0.
Scott DA, Denton MJ. Spinal cord protection in aortic endovascular surgery. Br J Anaesth. 2016;117(Suppl 2):ii26–31. https://doi.org/10.1093/bja/aew217.
Acknowledgements
Not applicable
Funding
This report received no funding.
Author information
Authors and Affiliations
Contributions
TW: writing, reviewing and editing manuscript. HS: operating surgery, reviewing and editing manuscript. KK: reviewing manuscript. TT: reviewing manuscript. TT: reviewing manuscript. SM: reviewing and editing manuscript. All authors read and approved the final manuscript.
Corresponding author
Ethics declarations
Ethics approval and consent to participate
Not applicable.
Consent for publication
This patient consented to the reporting of this case in scientific publication.
Competing interests
The authors declare no competing of interest.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
About this article
Cite this article
Wada, T., Sako, H., Kizu, K. et al. Endoscopic-assisted descending aortic replacement through a small intercostal incision: a case report. J Cardiothorac Surg 17, 305 (2022). https://doi.org/10.1186/s13019-022-02059-3
Received:
Accepted:
Published:
DOI: https://doi.org/10.1186/s13019-022-02059-3