Computed tomography-guided lung biopsy with rapid on-site evaluation for diagnosis of lung lesions: a meta-analysis

Abstract

Background

Lung biopsy (LB) procedures performed with computed tomography (CT guidance can enable the reliable diagnosis of lung lesions. These diagnostic efforts can be further expedited through a rapid on-site evaluation (ROSE) approach, allowing for the rapid assessment of collected tissue samples to gauge the adequacy of these samples, their features, and associated cytomorphological characteristics. The present analysis was developed to examine the safety and efficacy of CT-guided LB with ROSE as a means of diagnosing lung lesions.

Methods

Studies published as of July 31, 2022 in the PubMed, Embase, and Wanfang databases were identified for this meta-analysis. Diagnostic accuracy was the primary endpoint, while secondary endpoints included the operative duration, the number of punctures, and rates of lung hemorrhage, pneumothorax, and secondary LB.

Results

This meta-analysis included 6 total studies. Relative to CT alone, CT with ROSE was associated with a significant increase in diagnostic accuracy (P < 0.00001). In contrast, there were no significant differences between these two groups with respect to the operative duration (P = 0.86), the number of punctures (P = 0.60), or the rates of pneumothorax (P = 0.82) or lung hemorrhage (P = 0.81). Pooled secondary LB rates were significantly lower for patients that underwent CT with ROSE relative to patients in the CT only group (P = 0.0008). Significant heterogeneity was detected for the operative duration (I2 = 94%) and number of punctures (I2 = 98%) endpoints, while no publication bias was detected for any study endpoints.

Conclusions

These results suggest that ROSE may contribute to significant improvements in the diagnostic accuracy of CT-guided LB without contributing to higher rates of complications.

Peer Review reports

Introduction

Lung biopsy (LB) is a standard approach that is used for the safe and reliable diagnosis of nodules and masses present within the lungs [1,2,3]. Prior work suggests that the actual diagnostic accuracy of LB procedures can range from 65 to 94% [4,5,6,7], with a range of factors including the lesion size, needle type (core vs. fine needle), and imaging guidance technique (bronchoscopy, computed tomography [CT], or CT fluoroscopy) all impacting these diagnostic yields [5,6,7,8]. A failure to obtain an adequate biopsy specimen has been suggested to be an important cause of the misdiagnosis of lung malignancies in some reports [8, 9].

Rapid on-site evaluation (ROSE) offers an approach to rapidly conduct cytomorphological characteristics of tissues obtained from biopsy procedures in order to gauge their adequacy and malignancy. ROSE procedures performed by experienced pathologists can contribute to improved LB diagnostic accuracy [10]. ROSE techniques have been frequently employed in the context of bronchoscopy-guided biopsy procedures [10,11,12,13,14,15]. In contrast, there have been fewer studies regarding the application of ROSE approaches in the context of CT-guided LB [16,17,18,19,20,21,22]. As the results from an individual have the potential to be subject to bias derived from many sources, meta-analyses are warranted to mitigate such bias and to improve the overall statistical power of associated results [23].

Accordingly, the present study was conducted with the goal of examining the safety and diagnostic efficacy of combining CT-guided LB and ROSE approaches when evaluating lung lesions.

Materials and methods

Study selection

This meta-analysis was conducted based on Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines [24]. All studies published as of July 31, 2022 in the PubMed, Embase, and Wanfang databases were identified with the following search strategy: ((((Computed Tomography) OR (CT)) AND ((lung) OR (pulmonary))) AND (biopsy)) AND ((Rapid On-Site Evaluation) OR (ROSE)). This meta-analysis was registered at INPLASY.COM (No. INPLASY202280063).

Inclusion criteria:

  1. (a)

    Types of studies: comparative studies;

  2. (b)

    Diseases: lung lesions necessitating CT-guided LB;

  3. (c)

    Types of interventions: CT-guided LB with ROSE versus CT-guided LB only;

  4. (d)

    Languages: no limitations.

Exclusion criteria:

  1. (a)

    single-arm studies;

  2. (b)

    duplicate studies;

  3. (c)

    non-human studies;

  4. (d)

    case reports, letters, and reviews.

Data extraction and quality assessment

Two researchers (D.W. and T.W.) independently extracted baseline study data (first author, country, year of publication, study design, and quality scores), baseline patient data (number of patients, gender ratio, patient age, lesion diameter, lesion-pleura distance, and final diagnosis), and outcome data (diagnostic accuracy, number of punctures, operative duration, complications, and secondary LB rates). Discrepancies were resolved by a third investigator (YY. L.).

The Cochrane risk of bias tool was used to examine the quality of randomized controlled trials (RCTs) based on random sequence generation, allocation concealment, participant and personnel blinding, outcome assessment blinding, selective reporting, incomplete data, and other forms of bias.

Non-RCT quality was assessed using the Newcastle–Ottawa scale (NOS), consisting of criteria pertaining to selection (4 points), comparability (2 points), and outcomes (3 points) [25]. High-quality studies were those with a NOS score ≥ 7.

Endpoints

Diagnostic accuracy was the primary endpoint for this study, and was considered positive if the biopsy-based diagnosis was consistent with the final pathological diagnosis. Secondary study endpoints included operative duration, numbers of punctures, and the rates of pneumothorax, lung hemorrhage, and secondary LB. The secondary LB was conducted if the primary LB failed to obtain sufficient sample for the pathological diagnosis [17]. The operation duration was defined as the time from patients lying on the CT bed to getting out of the CT bed. In ROSE group, the operation time contained the CT-guided LB and ROSE time.

Meta-analysis

RevMan v5.3 was used to conduct pooled analyses. Continuous variables were compared using mean difference (MD) values and 95% confidence intervals (CIs), while categorical variables were compared based on pooled odds ratios (ORs) and 95% CIs. Heterogeneity was analyzed with the I2 statistic and the Q test, with significant heterogeneity being denoted by an I2 > 50%. Random-effects models were used in the context of significant heterogeneity, while fixed-effects models were otherwise conducted. A leave-one-out approach was used to perform sensitivity analyses aimed at determining the sources of any heterogeneity. Egger’s test was used to detect possible publication in Stata v12.0, and P < 0.05 was established as the threshold of significance.

Results

Study selection

The initial search strategy yielded 1,002 studies, of which 785 were retained following the removal of duplicate entries. In total, 7 studies were incorporated into the final meta-analysis [16,17,18,19,20,21,22]. For further details regarding the study selection process, see Fig. 1.

Fig. 1
figure 1

Flowchart diagram of our meta-analysis

Of these 7 studies, 2 were RCTs [16, 18] while 5 were retrospective in nature [17, 19,20,21,22]. Both RCTs exhibited an unclear risk of bias with respect to performance, detection, and reporting (Fig. 2). NOS scores for the included retrospective analyses ranged from 7–8. Core needles were used for LB procedures in 4 studies [17, 20,21,22], while 1 used a fine needle biopsy approach [19], and two studies did not specify the needle type(s) used [16, 18] (Table 1).

Fig. 2
figure 2

Cochrane risk-of-bias tool for the included RCTs

Table 1 Baseline data of the studies

These studies included 748 and 673 patients who respectively underwent CT-guided LB procedures with and without ROSE (Table 2). Baseline data were comparable between these two patient groups in all studies.

Table 2 Baseline data of the patients in these studies

Diagnostic accuracy

In total, 4 studies reported diagnostic accuracy rates [17, 18, 21, 22]. These pooled diagnostic accuracy rates were significantly higher for patients who underwent CT-guided LB with ROSE relative to those who underwent CT-guided LB alone (94.0% vs. 83.2%, OR: 3.16, P < 0.00001, Fig. 3a). No significant heterogeneity was detected (I2 = 0%), and Egger’s test revealed no evidence of publication bias (P = 0.243) (Table 3).

Fig. 3
figure 3figure 3

a The pooled diagnostic accuracy rate was significantly higher in CT-guided LB with ROSE group than that in CT-guided LB alone group; b The pooled pneumothorax rates were comparable between 2 groups; c The pooled lung hemorrhage rates were comparable between 2 groups; d The pooled operative time was comparable between 2 groups; e The pooled numbers of puncture were comparable between 2 groups; and f The pooled secondary LB rate was significantly lower in CT-guided LB with ROSE group than that in CT-guided LB alone group

Table 3 Subgroup analyses based on the use of core needle

Pneumothorax

Pneumothorax rates were provided in 6 studies [16,17,18,19,20,21], and these rates did not differ significantly between the two study groups (13.0% vs. 12.2%, OR: 1.04, P = 0.82, Fig. 3b). No significant heterogeneity was detected for this endpoint (I2 = 35%), and Egger’s test revealed no evidence of publication bias (P = 0.441).

Lung hemorrhage

Lung hemorrhage rates were provided in 6 studies [16,17,18,19,20,21], and these rates did not differ significantly between the two study groups (11.6% vs. 11.3%, OR: 1.05, P = 0.81, Fig. 3c). No significant heterogeneity was detected for this endpoint (I2 = 0%), and Egger’s test revealed no evidence of publication bias (P = 0.57).

Operative duration

Four studies reported data pertaining to operative duration [16,17,18, 20]. No significant differences in these pooled operative duration values were observed when comparing study groups (MD: -0.14, P = 0.86, Fig. 3d). Significant heterogeneity was detected for this endpoint (I2 = 94%), but sensitivity analyses failed to establish the source of this heterogeneity. Egger’s test revealed no evidence of publication bias (P = 0.181).

Number of punctures

Three studies provided data regarding the number of punctures [16, 18, 20], with no significant differences in this number between study groups in pooled analyses (MD: − 0.23, P = 0.60, Fig. 3e). Significant heterogeneity was detected for this endpoint (I2 = 98%), and the study performed by Liu et al. [18] was identified as the source of this heterogeneity in a sensitivity analysis. study. Egger’s test revealed no evidence of publication bias (P = 0.455).

Secondary LB rates

Secondary LB rates were reported in 3 studies [16,17,18]. A significantly lower secondary LB rate was evident for patients who underwent CT-guided LB with ROSE relative to patients who underwent CT-guided LB alone (4.8% vs. 16.7%, OR 0.25, P = 0.0008, Fig. 3f). No significant heterogeneity was detected (I2 = 0%), and Egger’s test revealed no evidence of publication bias (P = 0.102).

Subgroup analyses

Subgroup analyses were performed for patients that underwent core needle biopsy procedures. Data regarding diagnostic accuracy rates, operative duration, and the rates of pneumothorax and lung hemorrhage were successfully pooled for this analysis. Significantly higher pooled diagnostic accuracy rates were observed for patients who underwent ROSE relative to those who did not (P < 0.0001). In contrast, similar pooled pneumothorax rates (P = 0.19), lung hemorrhage rates (P = 0.59), and operative time (P = 1.00) were evident in these study groups.

Discussion

In this meta-analysis, diagnostic efficacy and safety outcomes were compared for the CT-guided LB of lung lesions with or without the incorporation of a ROSE approach. Overall, these pooled analyses revealed that ROSE contributed to significant improvements in CT-guided LB diagnostic accuracy without prolonging the operative duration or increasing rates of procedure-related complications as compared to CT-guided LB alone.

Diagnostic accuracy is the most important outcome in studies analyzing CT-guided LB approaches [2, 26, 27]. In the present report, ROSE was found to significantly improve these diagnostic rates by approximately 10.8% relative to CT-guided LB alone, while also significantly decreasing the rates of secondary LB in evaluated patients. This is consistent with the ability of ROSE to provide rapid insight regarding the cytomorphological adequacy and other characteristics of LB samples such that these ROSE-based preliminary diagnoses can be used to guide subsequent patient management [18].

ROSE-based diagnoses were highly consistent with final pathological diagnoses, with accurate rates ranging from 89.3 to 95.7% [18, 21]. As ROSE relies on the rapid staining of cell smears, however, it is not sufficient as a final diagnostic tool given that it fails to provide any histological or morphological information and cannot differentiate between lung cancer pathological subtypes, instead only allowing clinicians to judge whether a given lung lesion is malignant or benign [18].

The most common complications associated with CT-guided LB procedures include lung hemorrhage and pneumothorax. In the present analysis, no differences in the rates of either of these complications were observed when comparing CT-guided LB procedures performed with and without ROSE. As no significant heterogeneity was observed for these endpoints, this also suggests that these results are stable. Prior research has suggested that factors that do impact the rates of these CT-guided LB-related complications include emphysema, small lesions, non-prone positioning, a longer lesion-pleura distance, and a greater number of needle pathways [4, 21, 26, 28]. No significant differences in the pooled number of punctures were observed when comparing these two groups, potentially explaining why no reduction in safety for the CT-guided LB procedure was observed with ROSE incorporation.

Operative duration was comparable in both groups. While the ROSE procedure does require some time to complete the requisite dying and associated analyses, operator proficiency can effectively limit this time such that no significant differences in operative duration were observed with the integration of ROSE into the LB workflow. However, this endpoint was subject to significant heterogeneity. The significant heterogeneity may be subject to bias in retrospective studies, and different operators’ skill and experence. Further well designed prospective studies should be conducted to vadilate this result.

Core needle use can achieve greater levels of sample adequacy relative to fine needle use [6]. Accordingly, subgroup analyses for core needle biopsy procedures were performed, revealing that ROSE significantly improved CT-guided core needle biopsy diagnostic accuracy without any adverse safety-related outcomes.

There are certain limitations to this meta-analysis. For one, the majority of the included studies were retrospective in nature and thus subject to a high risk of bias. In addition, the majority of these studies incorporated several lung lesion types, including both lung masses and lung nodules. Moreover, one study did not specify the needle type used for biopsy procedures, which is an important consideration given that needle type can impact both diagnostic accuracy and complication rates. This may have impacted the results of needle type-based subgroup analyses performed herein. Fourth, all included studies were conducted in China, and additional meta-analyses should thus aim to incorporate data derived from other clinical research centers throughout the world.

Conclusion

In summary, these results suggest that the incorporation of ROSE procedures into the LB workflow may significantly improve CT-guided LB diagnostic accuracy without compromising the safety of this approach.

Abbreviations

CT:

Computed tomography

LB:

Ung biopsy

NOS:

Newcastle-Ottawa scale

RCT:

Randomized controlled trial

ROSE:

Rapid on-site evaluation

References

  1. Bourgouin PP, Rodriguez KJ, Fintelmann FJ. Image-guided percutaneous lung needle biopsy: how we do it. Tech Vasc Interv Radiol. 2021;24: 100770.

    Article  PubMed  Google Scholar 

  2. Brioulet J, David A, Sagan C, Cellerin L, Frampas E, Morla O. Percutaneous CT-guided lung biopsy for the diagnosis of persistent pulmonary consolidation. Diagn Interv Imaging. 2020;101:727–32.

    Article  CAS  PubMed  Google Scholar 

  3. Besa C, Huele A, Bächler P, Cruz F. Percutaneous CT-guided cutting needle biopsy of pulmonary lesions: retrospective analysis of 153 procedures. Rev Med Chil. 2013;141:449–56.

    Article  PubMed  Google Scholar 

  4. Fu YF, Li GC, Xu QS, Shi YB, Wang C, Wang T. Computed tomography-guided lung biopsy: a randomized controlled trial of low-dose versus standard-dose protocol. Eur Radiol. 2020;30:1584–92.

    Article  PubMed  Google Scholar 

  5. Fu YF, Zhang JH, Wang T, Shi YB. Endobronchial ultrasound-guided versus computed tomography-guided biopsy for peripheral pulmonary lesions: a meta-analysis. Clin Respir J. 2021;15:3–10.

    Article  PubMed  Google Scholar 

  6. Li Y, Yang F, Huang YY, Cao W. Comparison between computed tomography-guided core and fine needle lung biopsy: a meta-analysis. Medicine (Baltimore). 2022;101: e29016.

    Article  PubMed  Google Scholar 

  7. Fu YF, Li GC, Cao W, Wang T, Shi YB. Computed tomography fluoroscopy-guided versus conventional computed tomography-guided lung biopsy: a systematic review and meta-analysis. J Comput Assist Tomogr. 2020;44:571–7.

    Article  PubMed  Google Scholar 

  8. Yeow KM, Tsay PK, Cheung YC, Lui KW, Pan KT, Chou AS. Factors affecting diagnostic accuracy of CT-guided coaxial cutting needle lung biopsy: retrospective analysis of 631 procedures. J Vasc Interv Radiol. 2003;14:581–8.

    Article  PubMed  Google Scholar 

  9. Hiraki T, Mimura H, Gobara H, Iguchi T, Fujiwara H, Sakurai J, et al. CT fluoroscopy-guided biopsy of 1000 pulmonary lesions performed with 20-gauge coaxial cutting needles: diagnostic yield and risk factors for diagnostic failure. Chest. 2009;136:1612–7.

    Article  PubMed  Google Scholar 

  10. Huang Z, Zhuang D, Feng A, Ye L, Hong L. Real-time and accuracy of rapid on-site cytological evaluation of lung cancer. Transl Cancer Res. 2021;10:479–86.

    Article  PubMed  PubMed Central  Google Scholar 

  11. Lin CK, Jan IS, Yu KL, Chang LY, Fan HJ, Wen YF, et al. Rapid on-site cytologic evaluation by pulmonologist improved diagnostic accuracy of endobronchial ultrasound-guided transbronchial biopsy. J Formos Med Assoc. 2020;119:1684–92.

    Article  PubMed  Google Scholar 

  12. Chen CH, Cheng WC, Wu BR, Chen CY, Chen WC, Hsia TC, et al. Improved diagnostic yield of bronchoscopy in peripheral pulmonary lesions: combination of radial probe endobronchial ultrasound and rapid on-site evaluation. J Thorac Dis. 2015;7:S418–25.

    PubMed  PubMed Central  Google Scholar 

  13. Jain D, Allen TC, Aisner DL, Beasley MB, Cagle PT, Capelozzi VL, et al. Rapid on-site evaluation of endobronchial ultrasound-guided transbronchial needle aspirations for the diagnosis of lung cancer: a perspective from members of the pulmonary pathology society. Arch Pathol Lab Med. 2018;142:253–62.

    Article  PubMed  Google Scholar 

  14. Madan K, Dhungana A, Mohan A, Hadda V, Jain D, Arava S, et al. Conventional transbronchial needle aspiration versus endobronchial ultrasound-guided transbronchial needle aspiration, with or without rapid on-site evaluation, for the diagnosis of sarcoidosis: a randomized controlled trial. J Bronchology Interv Pulmonol. 2017;24:48–58.

    Article  PubMed  Google Scholar 

  15. Sehgal IS, Dhooria S, Aggarwal AN, Agarwal R. Impact of rapid on-site cytological evaluation (ROSE) on the diagnostic yield of transbronchial needle aspiration during mediastinal lymph node sampling: systematic review and meta-analysis. Chest. 2018;153:929–38.

    Article  PubMed  Google Scholar 

  16. Huang Y, Xia L, Tang C, Yi S, Yang Z. Application research of cell rapid on-site evaluation in CT-guided percutaneous lung biopsy. Chong Qing Yi Xue. 2020;49:2885–8.

    Google Scholar 

  17. Li Y, Li K, Wang X, Shan C, Li C. Rapid on-site evaluation in CT-guided percutaneous biopsy of peripheral pulmonary nodules. Chin J Interv Imaging. 2020;17:18–21.

    Google Scholar 

  18. Liu W, Xu C, Li L, Yuan Q, Wang W, Zou J. The value of computed tomography-guided percutaneous lung biopsy combined with rapid on-site evaluation in diagnosis of peripheral pulmonary nodules. Technol Cancer Res Treat. 2022;21:15330338221118718.

    Article  PubMed  PubMed Central  Google Scholar 

  19. Peng TF, Ren T, Wang HS, Feng ZX, Wang MF. Diagnostic value of rapid on-site evaluation for CT-guided percutaneous fine needle aspiration in the diagnosis of pulmonary occupying lesions. Biomed Res Int. 2020;2020:9842768.

    Article  PubMed  PubMed Central  Google Scholar 

  20. Wang C, Wang Y, Yang Q. The application of rapid on-site cytological evaluation for percutaneous lung biopsy. Tianjin Med J. 2021;49:94–7.

    Google Scholar 

  21. Yiminniyaze R, Zhang X, Zhang Y, Chen K, Li C, Zhu N, et al. Diagnostic efficiency and safety of rapid on-site evaluation combined with CT-guided transthoracic core needle biopsy in suspected lung cancer patients. Cytopathology. 2022;33:439–44.

    Article  PubMed  PubMed Central  Google Scholar 

  22. Zhang L, Tao L, Wang X, Li X, Wang Y, Zhang Y. Application of C-ROSE combined with 4D navigation-guided CT localization in percutaneous puncture lung biopsy. China Med Equip. 2021;18:99–102.

    Google Scholar 

  23. Lee YH. An overview of meta-analysis for clinicians. Korean J Intern Med. 2018;33:277–83.

    Article  PubMed  Google Scholar 

  24. Moher D, Shamseer L, Clarke M, Ghersi D, Liberati A, Petticrew M, et al. Preferred reporting items for systematic review and meta-analysis protocols (PRISMA-P) 2015 statement. Syst Rev. 2015;4:1.

    Article  PubMed  PubMed Central  Google Scholar 

  25. Stang A. Critical evaluation of the Newcastle-Ottawa scale for the assessment of the quality of nonrandomized studies in meta-analyses. Eur J Epidemiol. 2010;25:603–5.

    Article  PubMed  Google Scholar 

  26. Huang YY, Cheng H, Li GC. Computed tomography-guided core needle biopsy for lung nodules: low-dose versus standard-dose protocols. Wideochir Inne Tech Maloinwazyjne. 2021;16:355–61.

    PubMed  PubMed Central  Google Scholar 

  27. Zlevor AM, Mauch SC, Knott EA, Pickhardt PJ, Mankowski Gettle L, Mao L, et al. Percutaneous lung biopsy with pleural and parenchymal blood patching: results and complications from 1112 core biopsies. J Vasc Interv Radiol. 2021;32:1319–27.

    Article  PubMed  Google Scholar 

  28. Li GC, Fu YF, Cao W, Shi YB, Wang T. Computed tomography-guided percutaneous cutting needle biopsy for small (≤ 20 mm) lung nodules. Medicine (Baltimore). 2017;96: e8703.

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

None.

Funding

None.

Author information

Authors and Affiliations

Authors

Contributions

PX designed this work. TW and YYH searched the articles. DW, YYH, and YYL performed the data extraction and statistical analyses. DW and YYL wrote this article. All authors approved the final version of this paper. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Ping Xia.

Ethics declarations

Ethics approval and consent to participate

This is a meta-analysis and ethics approval and consent to participate are not required.

Consent for publication

This is a meta-analysis and consent for publication is not required.

Availability of data and materials: The data that support the findings of this study are available from the corresponding author upon reasonable request.

Competing interests

The authors declared that they have no Competing interests.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Wu, D., Liu, YY., Wang, T. et al. Computed tomography-guided lung biopsy with rapid on-site evaluation for diagnosis of lung lesions: a meta-analysis. J Cardiothorac Surg 18, 122 (2023). https://doi.org/10.1186/s13019-023-02212-6

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13019-023-02212-6

Keywords