Placement of stent grafts with different calibers into the true and false lumens of anastomotic aneurysms after descending aortic replacement for aortic dissection

Abstract

Anastomotic aneurysms present as a life-threatening emergency after descending aortic replacement for aortic dissection. Thoracic endovascular aneurysm repair (TEVAR) has been performed since the early 2000s for complicated cases in which re-thoracotomy cannot be adopted. We report the case of a 57-year-old male patient, during a 5-year follow-up after descending aortic replacement for aortic dissection, developed aneurysm expansion around the false lumen on the peripheral side of the artificial graft. Considering the risk and the patient’s desires, we opted to perform TEVAR with different calibers into the true and false lumens “modified kissing stents technique”. His postoperative course was uneventful without any complications. This case highlights the utility of the modified kissing stents technique for anastomotic aneurysms after descending aortic replacement for aortic dissection using stent grafts with different calibers into the true and false lumens.

Peer Review reports

A 57-year-old male patient developed Stanford type B aortic dissection with entry on the distal side of the left subclavian artery. During a follow-up, the diameter of aortic aneurysm from the entry to Th9-10 expanded to 60 mm. We adopted a policy that descending aortic replacement (Triplex graft 22 mm, Terumo Corporation, Tokyo, Japan) from just below the left subclavian artery to Th9-10 should be performed because the length of the proximal landing zone in TEVAR would run short. During a 5-year follow-up after descending aortic replacement for aortic dissection, developed aneurysm expansion around the false lumen on the peripheral side of the artificial graft. A computed tomography (CT) and angiography revealed an expanded aneurysm with the saccular aneurysm (61 mm) around the false lumen on the peripheral side of the artificial graft anastomosed with a double-barrel technique (Fig. 1A–C). The diameters of the true and false lumen were 11 and 38 mm, respectively. Regarding the kinds of surgical interventions, we considered performing TEVAR only in the true lumen, direct coil embolization with a plug above the right renal artery, and fenestration above the right artery. However, there were some problems such as the possibility of re-entry between the pseudoaneurysm and the embolization, the cost of coils, and the possibility of leg ischemia by changes in blood flow induced by fenestration. We adopted a policy that thoracic endovascular aortic repair (TEVAR) with different calibers into the true and false lumens should be performed to perfuse both the true and false lumens considering the difference in lumen sizes, the conditions of abdominal branch vessels (Fig. 1D–H), and the patient’s desires.

Fig. 1
figure 1

Preoperative findings. A Contrast-enhanced computed tomography (CT) scan. B Angiography of an expanded aneurysm with the saccular aneurysm. Each marker (, ▲, and #) shows the same. C Three-dimensional-CT. DH Celiac artery (D), superior mesenteric artery (E), and left renal artery F from the true lumen. Right renal artery (G) and inferior mesenteric artery H from the false lumen. Each artery is shown as a yellow triangle

The procedure was performed under general anesthesia. Both common femoral arteries were exposed. After exposing both common femoral arteries (CFAs), wires were inserted through the left CFA into the true lumen and through the right CFA into the false lumen, while checking with intravascular ultrasound. Excluder contralateral leg of 16–115 mm (W.L. Gore & Associates Inc, Flagstaff, Ariz) and Conformable Gore TAG (CTAG) device of 34–100 mm were placed on the true and false lumens, respectively. An additional Excluder contralateral leg of 18–135 mm in the true lumen and an additional CTAG of 37–100 mm in the false lumen were added just above the celiac artery (Fig. 2A). A balloon touch-up was simultaneously performed. Nevertheless, an Excluder aorta extender of 36–45 mm was additionally placed because type 1b endoleak around the false lumen was observed. His postoperative course was uneventful without any serious perioperative complications. Good flow in both lumens, no endoleak, and good stent-graft positioning were observed on the CT during the follow-up after three months (Fig. 2B). The patient's course remained uneventful at seven months after surgery.

Fig. 2
figure 2

Intra- and postoperative findings. A Intraoperative findings under digital subtraction angiography. B Postoperative contrast-enhanced computed tomography scan

The use of TEVAR in patients with chronic type B aortic dissection, however, remains controversial. As in our case, one study reported that the kissing stent technique for chronic aortic dissection completely preserved blood flow to abdominal branch vessels and excluded the aneurysm by implanting the stent graft landing on the false and true lumen [1] Indeed, our case with a significant difference in vessel diameter between the true and false lumen was challenging for performing TEVAR only on the true lumen. In contrast to the previous methods of inserting stent grafts of the same diameter, our modified kissing stent technique, insertion of stent grafts with different diameters, was performed. In particular, we tried to carefully perform simultaneous touch-up to prevent the small stent graft from crushing during implantation.

This case provides valuable insight into the modified kissing stents technique using stent grafts with different calibers for aortic dissection, highlighting the importance of appropriate surgical intervention as one of the alternative treatments for patients with difficult surgical situations or refusal of open surgery.

Availability of data and materials

The datasets used are available from the corresponding author upon reasonable request.

Abbreviations

CT:

Computed tomography

TEVAR:

Thoracic endovascular aortic repair

CFA:

Common femoral artery

CTAG:

Conformable Gore TAG

Reference

  1. Yoshitake A, Hachiya T, Hayashi K, Shimizu H. The kissing stents technique for a patient with chronic type B aortic dissection. J Thorac Cardiovasc Surg. 2015;150:995–7.

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

We would like to thank Editage (www.editage.com) for English language editing.

Funding

None.

Author information

Authors and Affiliations

Authors

Contributions

HU and TI designed the study, analyzed the data, and wrote the manuscript. MU helped in gathering patient information, performed data analysis, and wrote the manuscript. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Masateru Uchiyama.

Ethics declarations

Ethics approval and consent to participate

Ethics approval and consent for this study have been obtained from participants.

Consent for publication

All subjects enrolled in this research have given their informed consent which alongside the described protocol.

Competing interests

All authors have no conflict of interest to disclosure as described by Journal of Cardiothoracic Surgery.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Uehara, H., Uchiyama, M. & Imazuru, T. Placement of stent grafts with different calibers into the true and false lumens of anastomotic aneurysms after descending aortic replacement for aortic dissection. J Cardiothorac Surg 19, 9 (2024). https://doi.org/10.1186/s13019-023-02477-x

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13019-023-02477-x

Keywords