- Case report
- Open access
- Published:
Totally robotic repair of atrioventricular septal defect in the adult
Journal of Cardiothoracic Surgery volume 10, Article number: 156 (2015)
Abstract
Background
Atrioventricular septal defect (AVSD) accounts for up to 3 % of congenital cardiac defects, which is routinely repaired via median sternotomy. Minimally invasive approach such as endoscopic or robotic assisted repair for AVSD has not been reported in the literature. With the experience with robotic mitral valve surgery and congenital defect repair, we initiated robotic AVSD repair in adults.
Case Presentation
In this report, we presented three cases of successful repair of partial and intermediate AVSD by using da Vinci SI surgical system (Intuitive Surgical, Inc., Sunnyvale, CA).
Conclusions
Totally robotic AVSD repair via right atriotomy could be safely performed in adults and it may provide superior cosmesis with the comparable surgical outcome of the repair via sternotomy.
Background
Atrioventricular septal defect (AVSD) makes up to 3Â % of all congenital cardiac defects, which is predominantly repaired via median sternotomy [1]. Totally robotic repair of AVSD has not been reported in the literature to our knowledge. We describe our experience with three cases of atrioventricular septal defect repair by using da Vinci SI surgical system (Intuitive Surgical, Inc., Sunnyvale, CA).
Case presentation
Patient 1 A 33Â year-old lady who had detected heart murmur for 6Â years presented with recent onset of palpitation and chest discomfort. She was admitted in July 2011 and trans-thoracic echocardiography (TTE) suggested an ostium primum atrial septal defect (ASD) (2.2Â cm in diameter) with left to right intracardiac shunt, and a 0.2Â cm mitral valve cleft with moderate mitral regurgitation (MR). The interventricular septum was intact. The pulmonary artery pressure was 38Â mmHg and mild tricuspid regurgitation was present. She was diagnosed with partial AVSD.
Patient 2 A 24Â year-old lady was admitted due to detected heart murmur for 5Â years in December 2014. TTE suggested an ostium primum ASD (1.2Â cm) with mitral valve cleft and moderate MR whilst a patent foramen ovale (PFO) (0.2Â cm) and a perimembranous ventricular septal defect (VSD) (0.3Â cm) were also present with left to right shunt. The left atrium was dilated (3.6Â cm in diameter). The ventricles were normal with LVEF of 76Â %. She was diagnosed with intermediate AVSD and PFO.
Patient 3 A 27Â year-old lady was admitted because of heart murmur detected 4Â months before in January 2015. TTE suggested a sucundum ASD (2Â cm) co-existing with an ostia primum ASD (2Â cm) and a 1.1Â cm mitral valve cleft, which caused left to right shunt and moderate MR. The pulmonary artery pressure was 41Â mmHg and mild tricuspid regurgitation was seen. The right heart was dilated and the diameters of RA and RV were 4.6Â cm and 4.3Â cm respectively. The left heart was normal and LVEF was 58Â %. The diagnosis was partial AVSD and sucundum ASD.
All three patients had normal peripheral vasculatures confirmed by ultrasonic scan and the informed consent was taken for totally robotic repair of AVSD before surgery.
During surgery, general anaesthesia was induced and CPB was set up through peripheral vessels according to our protocol [2, 3]. After systemic heparinization, femoral arterial (17 F to 22 F) and venous (21 F or 23 F) cannulation (Metronic, Minneapolis, Minn) was performed through a 2-cm transverse incision at the right groin under the guidance of TEE. Bicaval venous drainage was instituted through the jugular and femoral/inferior vena cava cannulas. The robotic camera and instrument arms were inserted with a working port made in the right chest (Fig. 1). The pericardium was opened and the aorta was cross clamped after CPB began. The heart was arrested with single dose of antegrade cold HTK cardioplegic solution given directly through anterior chest using a 14GA angiocatheter, and endoscopic snaring of the vena cavae with umbilical cords was performed.
Via right atriotomy, mitral valve was examined (Fig. 2a) and the cleft between the left superior and inferior leaflets was repaired using three to four interrupted 4–0 Goretex sutures and saline injection test was performed (Fig. 2b). Six to seven interrupted 4–0 pledgted Gore-Tex mattress sutures were placed along the crest of interventricular septum from the right ventricular side (Fig. 2c). In one case where a small VSD co-existed, the mattress sutures were placed beneath the lower margin of the VSD and brought directly through the crest of ventricular septum for the primary closure of VSD. After measurement of the dimension between the superior and inferior commissures was made, a Dacron patch was prepared according to the shape and size of the ostium primum ASD. Then, the mattress sutures were brought through the lower margin of the patch to secure it into the crest of ventricular septum, either by knot tying pusher or Cor-Knot™ tying device (LSI Solutions, Victor, NY). Then two 4–0 Gore-Tex running sutures were used to close the ASD from the upper and lower commissures. The inferior suture was continued below the Thebesian valve to avoid injury to the conduction tissue with the coronary sinus draining into the left atrium. PFO or secundum ASD was closed separately. The right atriotomy was closed with double layers of 4–0 Goretex running suture and CPB was weaned as routine.
All three patients were off bypass easily. The total CPB time was 195Â min, 128Â min, and 126Â min for the first, second and the third patients, and aorta cross clamping time was 126Â min, 88Â min and 80Â min respectively. Intraoperative TEE excluded residual shunt and regurgitation of mitral or tricuspid valves. The patients were ventilated for 15 to 16Â h in critical care ward and they all had an uneventful recovery postoperatively. Postoperative TEE confirmed that the robotic repair of the defects was successful with no intracardiac shunt or MRÂ (Fig. 3). All patients were discharged within 1Â week of surgery.
Discussion
Unlike sucundum ASD and perimembranous VSD that can sometimes be occluded directly through the interventional procedure, AVSD is a more complex congenital heart defect and surgical repair is inevitable [1]. AVSD is conventionally repaired through median sternotomy, but no result on robotic repair of AVSD has been reported. Since most young adult patients are uneasy about the surgical wound, minimally invasive surgery is often sought by them. Although robotic cardiac surgery remains controversial due to steep learning curves, high expenses, long operation time, and highly selected patients, it has been developed over the last decade and is shown to improve cosmesis and quality of life after surgery [4]. We initiated the surgical repair of AVSD in 2011 and completed three cases so far.
Before robotic surgery, surgical approach had to be carefully planned to enable sufficient exposure and effective repair of the defects. Since right atriotomy through the right chest had provided us with excellent and reliable exposure of the right heart and the left atrium for robotic repair of ASD [3], VSD [2, 5], mitral valve [6], atrial mass [7, 8], and PS (data not published), the initial attempt of novel robotic repair of AVSD via right atriotomy was made with success. The long operation time was thought to be a shortcoming of robotic surgery. With robotic surgical experience gained, the operative duration could be significantly shortened. The aorta cross-clamping time decreased from 128Â min for the first case of AVSD to around 80Â min after performing a variety of robotic cardiac operations over a 3-year period.
The robotic surgical system has other advantages in the repair of AVSD. The endoscopic system provides the surgeon with excellent visualization of the delicate structure of the crest of septum and the surrounding valvular tissue with magnification higher than 10 times; hence, the injury to the cardiac conduction system could be effectively avoided. Besides, the surgical videos recorded is excellent media for surgical education.
Conclusions
Totally robotic AVSD repair via right atriotomy could be safely performed in adults by an experienced robotic cardiac surgeon. The robotic repair technique may provide superior cosmesis with the comparable surgical outcome of conventional AVSD repair via median sternotomy.
Consent
Written consent which had been approved by the institutional review board was taken from the patient for publication of this work and the associated images.
Abbreviations
- ASD:
-
Atrial septal defect
- AVSD:
-
Atrioventricular septal defect
- CPB:
-
Cardiopulmonary bypass
- MR:
-
Mitral regurgitation
- PFO:
-
Patent foramen ovale
- RA:
-
Right atrium
- TEE:
-
Transesophageal echocardiography
- TTE:
-
Transthoracic echocardiography
- VSD:
-
Ventricular septal defect
References
Funck-Brentano C, Webb GD, Walker H, Westby J, Ukkonen H, Trindade PT, et al. ESC Guidelines for the management of grown-up congenital heart disease (new version 2010). Eur Heart J 2010;31;2915–57.
Gao C, Yang M, Wang G, Xiao C, Wang J, Zhao Y. Totally endoscopic robotic ventricular septal defect repair in the adult. J Thorac Cardiovasc Surg 2012;144;1404–7.
Xiao C, Gao C, Yang M, Wang G, Wu Y, Wang J, et al. Totally robotic atrial septal defect closure: 7-year single-institution experience and follow-up. Interact Cardiovasc Thorac Surg 2014;19;933-7.
Yang M, Yao M, Wang G, Xiao C, Wu Y, Zhang H, et al. Comparison of postoperative quality of life for patients who undergo atrial myxoma excision with robotically assisted versus conventional surgery. J Thorac Cardiovasc Surg 2015;150;152-7.
Gao C, Yang M, Wang G, Wang J, Xiao C, Zhao Y. Totally endoscopic robotic ventricular septal defect repair. Innov Technol Tech Cardiothorac Vasc Surg 2010;5;278–80.
Gao C, Yang M, Xiao C, Wang G, Wu Y, Wang J, et al. Robotically assisted mitral valve replacement. J Thorac Cardiovasc Surg 2012;143;S64–7.
Gao C, Yang M, Wang G, Wang J. Totally robotic resection of myxoma and atrial septal defect repair. Interact Cardiovasc Thorac Surg 2008;7;947–50.
Gao C, Yang M, Wang G, Wang J, Xiao C, Wu Y, et al. Excision of atrial myxoma using robotic technology. J Thorac Cardiovasc Surg 2010;139;1282–5.
Acknowledgements
We thank Jiali Wang, Yao Wang, Nan Cheng and the nursing staff of the robotic cardiac surgical team of PLA General Hospital for their dedication in the patient care and help in the data collection.
Author information
Authors and Affiliations
Corresponding author
Additional information
Competing interests
The authors declare no competing interests.
Authors’ contributions
The operations were performed by CG and MY, CX and HZ assisted in the operations. MY and CX participated the patient’s perioperative care. MY and HZ wrote the manuscript. CG revised the manuscript and all authors read and approved the final manuscript.
Rights and permissions
Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
About this article
Cite this article
Gao, C., Yang, M., Xiao, C. et al. Totally robotic repair of atrioventricular septal defect in the adult. J Cardiothorac Surg 10, 156 (2015). https://doi.org/10.1186/s13019-015-0358-y
Received:
Accepted:
Published:
DOI: https://doi.org/10.1186/s13019-015-0358-y