Skip to main content

Difficult removal: a Swan-Ganz catheter coiled on the central venous catheter

Abstract

Background

The Swan-Ganz catheter plays an important role in gaining understanding of cardiac pathophysiology and in the hemodynamic monitoring of critically ill patients. Difficult removal of the Swan-Ganz catheter is a rare but serious complication.

Case presentation

This case presents the difficult removal of a Swan-Ganz catheter in a 28-year-old female patient after cardiac surgery. Fluoroscopy and chest X-ray revealed that a portion of the Swan-Ganz catheter was coiled on the central venous catheter at the level of the superior vena cava. Under X-ray guidance, the central venous catheter was first removed, and then the Swan-Ganz catheter was successfully withdrawn through the percutaneous introducer sheath.

Conclusions

This case report provides an unreported reason for difficult removal and describes a successful solution. This report suggests that X-ray examinations may be necessary before removing the Swan-Ganz catheter.

Peer Review reports

Background

Difficult removal of the Swan-Ganz catheter has been reported with an estimated incidence of 0.2–2.5% [1], due to reasons including intracardiac knots and kinks in the Swan-Ganz catheter [2,3,4,5,6]. Cardiac perforation and pulmonary artery rupture were the most severe complications due to the difficult removal of a catheter in a previous report [7, 8]. This case report features the difficult removal of a Swan-Ganz catheter, which coiled on the central venous catheter in a patient after cardiac surgery.

Case presentation

A 28-year-old woman, weight 55 kg and height 162 cm, initially presented to the emergency department of an outside hospital with a 2-month history of chest distress, cough and dyspnea. The patient’s symptoms did not improve significantly after oxygen therapy or anti-asthma medication combined with aerosol inhalation. The patient was later transferred to the cardiovascular surgery department in the authors’ institution with aggravation of the above symptoms. Echocardiography revealed severe tricuspid regurgitation and congenital heart disease, including a ventricular septal defect and rupture of the right coronary sinus aneurysm. An abdominal computed tomography scan revealed that the inferior vena cava and hepatic veins were widened. The preoperative laboratory examination was unremarkable. For invasive hemodynamic measurement, a Swan-Ganz catheter (Edwards Lifesciences, Irvine, CA) was inserted through an 8-F percutaneous introducer sheath placed in the right internal jugular vein, and a central venous catheter was inserted into the right subclavian vein without any difficulties. The pulmonary artery pressure waveform suggested that the catheter was successfully floated into the pulmonary artery. The patient underwent ventricular septal defect repair, aortoplasty and tricuspid valvuloplasty under cardiopulmonary bypass.

After obtaining the hemodynamic indexes postoperatively, the Swan-Ganz catheter was found difficult to withdraw when it was pulled out to 35 cm mark. The cardiovascular surgeons and intensive care physicians suggested transporting the patient to interventional radiology. The chest X-ray showed that a portion of the Swan-Ganz catheter coiled on the central venous catheters at the level of the superior vena cava and formed a knot approximately 1 cm in diameter (Fig. 1). Under X-ray guidance, the interventional radiologist first removed the central venous catheter smoothly. Then, the Swan-Ganz catheter was gently pushed into the right ventricle to provide more space to uncoil, and then the catheter returned to its original coiled configuration. Finally, the Swan-Ganz catheter was successfully withdrawn through the percutaneous introducer sheath. A closer inspection of the Swan-Ganz catheter coiled on the central venous catheter is shown in Fig. 2. During this procedure, the patient’s hemodynamics were not significantly affected, and the patient did not present any complications or cardiovascular injury. Valvar damage was excluded by echocardiography.

Fig. 1
figure 1

The Swan-Ganz catheter coiled on the central venous catheter at the level of the superior vena cava

Fig. 2
figure 2

A closer inspection of the Swan-Ganz catheter and central venous catheter after removal

Discussion and conclusion

The use of a Swan-Ganz catheter with balloon flotation is a feasible and rapid technique for hemodynamic monitoring in critically ill patients [9]. However, there have been continuous reports of complications related to the removal of Swan-Ganz catheter in clinical practice, and the common causes include intracardiac knots and kinks in the catheter (Table 1). In this case report, fluoroscopy and chest X-ray revealed that a portion of the catheter coiled on the central venous catheter and formed a knot. The cause of the knot is unknown, and the authors hypothesize that the catheter end may form a knot when the cardiothoracic surgeon reinserted the Swan-Ganz catheter into the distal portion of the pulmonary artery after performing tricuspid valve surgery under cardiopulmonary bypass. Therefore, the loop of the catheter may easily coil around the central venous catheter when the Swan-Ganz catheter is withdrawn. This case suggested that although pulmonary artery pressure wave may reflect the Swan-Ganz catheter successfully floated into the pulmonary artery, it could not indicate whether the catheter formed the intracardiac knot and kink.

Table 1 Difficult removal of the Swan-Ganz catheter

In this case report, the authors describe a successful management approach for removing a Swan-Ganz catheter. The key point for addressing loops and knots is to withdraw the central venous catheter with the assistance of radiologic techniques. Then, the Swan-Ganz catheter could be advanced into the right ventricle to provide more space for the catheter to uncoil. Finally, the catheter was withdrawn under X-ray guidance. This case report suggested that the surgeons should place the catheter in a normal coiled state before re-advancing the Swan-Ganz catheter intraoperatively to avoid forming knots and then gently place the catheter in the right ventricle. Additionally, it is important to take a chest X-ray before removing the Swan-Ganz catheter in patients undergoing tricuspid valve surgery. This process may help similar difficult removals of Swan-Ganz catheters, thereby eliminating the need for invasive maneuvers, but cannot be applied for tight knots.

Availability of data and materials

Not applicable.

References

  1. Dee Boyd K, Thomas SJ, Gold J, et al. A prospective study of complications of pulmonary artery catheterizations in 500 consecutive patients. Chest. 1983;84:245–9.

    Article  Google Scholar 

  2. Shang XK, Yan Y, Wang B. Successful retrieval of a knotted swan-Ganz catheter using interventional approach in an adult: a case report. Anaesthesiol Intensive Ther. 2016;48(5):367–70.

    Article  Google Scholar 

  3. Yuan H, Lee E, Patel A. Removal of pulmonary artery catheter knotted during placement by using transesophageal echocardiography. J Cardiothorac Vasc Anesth. 2010;24(6):1027–8.

    Article  Google Scholar 

  4. Chemchik H, Hassen MB, Turki M, et al. Intracardiac node of swan-Ganz catheter: report of a case. Pan Afr Med J. 2013;14:137.

    Article  Google Scholar 

  5. Manoj HI, Michael E. Difficult removal of a kinked swan-Ganz catheter. J Cardiothor Vas An. 2018;32(2):e41–2.

    Article  Google Scholar 

  6. James RB. Tao Hong, Manuel C. an unusual kinked pulmonary artery catheter causes difficult removal. J Cardiothor Vas An. 2012;26(5):e61–2.

    Article  Google Scholar 

  7. Fleisher AG, Tyers GF, Manning GT, et al. Management of massive hemoptysis secondary to catheter-induced perforation of the pulmonary artery during cardiopulmonary bypass. Chest. 1989;95:1340–1.

    Article  CAS  Google Scholar 

  8. Kearney TJ, Shabot MM. Pulmonary artery rupture associated with the swan-Ganz catheter. Chest. 1995;108:1349–52.

    Article  CAS  Google Scholar 

  9. Chatterjee K. The swan-Ganz catheters: past, present, and future: a viewpoint. Circulation. 2009;119(1):147–52.

    Article  Google Scholar 

Download references

Acknowledgements

Not applicable.

Funding

Key Young Medical Research Program of Jiangsu Province (QNRC2016587).

Author information

Authors and Affiliations

Authors

Contributions

Performed the anesthesia: J Shen and H Huang; Postoperative intensive care follow-up: LY Ma; Manuscript preparation: H Huang. All authors read and approved the final manuscript.

Corresponding author

Correspondence to He Huang.

Ethics declarations

Ethics approval and consent to participate

Our institution does not require ethical approval for reporting individual cases or case series.

Consent for publication

Written informed consent was obtained from the patient for their anonymized information to be published in this article.

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Shen, J., Ma, L. & Huang, H. Difficult removal: a Swan-Ganz catheter coiled on the central venous catheter. J Cardiothorac Surg 15, 103 (2020). https://doi.org/10.1186/s13019-020-01149-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13019-020-01149-4

Keywords