Figure of eight suture technique in aortic valve replacement decreases prosthesis-patient mismatch

Abstract

Background

While the pledget suture technique has been the standard for surgical aortic. valve replacement (AVR), discussion continues regarding the possibility of the nonpledget suture technique to produce superior structural and hemodynamic parameters. This study aims to assess the effectiveness of the figure-of-eight suture technique in AVR, as determined by the incidence of prosthesis-patient mismatch (PPM).

Methods

We reviewed records of patients (Nā€‰=ā€‰629) who underwent a surgical AVR procedure between January 2011 and July 2018 at a single institution. Indexed effective orifice area values and PPM incidence were calculated from implanted valve size and patient body surface area. Incidence of none, moderate, and severe PPM was compared across AVR suture techniques.

Results

A total of 570 pledget and 59 figure-of-eight patients were compared for incidence of PPM. Patients who received AVR with the pledget suture technique had significantly lower echocardiographic measurements of baseline ejection fraction than patients who had received AVR with the figure-of-eight suture technique (pā€‰=ā€‰0.003). Patients who received the figure-of eight suture had a 14% decrease in moderate PPM compared to patients who received the pledget suture (pā€‰=ā€‰0.022). Patients who received the figure-of-eight suture also had a significantly higher rate of no PPM (pā€‰=ā€‰0.044).

Conclusions

The use of the figure-of-eight suture technique in AVR can reduce the incidence of moderate PPM. While the pledget suture is the standard technique in AVR, the figure-of-eight suture technique may offer better structural and hemodynamic outcomes, especially for patients with a smaller aortic annulus.

Peer Review reports

Background

Aortic valve replacement (AVR) has evolved into the gold standard of treatment for severe aortic valve disease, with a 3.4% 30-day mortality rate and 3.2% rate of vascular complications [1]. Traditionally, AVR is performed by using interrupted sutures with nonabsorbable pledgets, which are placed under the aortic annular ring to secure the prosthetic valve. The pledget suture technique provides additional reinforcement that is particularly useful in patients with delicate, loose tissue in their aortic ring [2]. With their added support, pledget sutures can further prevent the onset of aortic regurgitation or paravalvular leaks (PVLs) [3]. PVLs follow a generally benign course after AVR, but in their moderate-to-severe forms, they can be a significant risk factor of post-operative mortality [4,5,6]. Pledget sutures are still met with caution, however, as they may increase the risk of endocarditis, pannus formation, aortic calcification, and reduced effective orifice area (EOA) [4, 7, 8]. Due to these concerns, the interrupted nonpledget suture technique has been considered in AVR, especially in younger patients who do not require significant valvular support. The nonpledget suture technique creates a larger EOA following implantation, which can better accommodate future transcatheter valve replacement (TAVR) and reduce prosthesis-patient mismatch (PPM). PPM describes the disproportion between the EOA of an implanted valve and the patientā€™s body size, and its presence can significantly impact long-term cardiac and mortality outcomes [14,15,16,17,18,19,20,21,22,23,24].

The pledget and nonpledget suture techniques carry unique differences in design and utility that effect their clinical outcomes in AVR. In comparison to the noneverting pledget technique, Tabata and colleagues found that the simple interrupted suture without pledgets can significantly reduce PPM in small-valve AVR [7]. Kim et al. [8] reproduced these findings in their institution and additionally reported an improved PPM reduction with the figure-of-eight suture technique without pledgets. Despite these results, past reports have found neither suture technique to be correlated with PPM and no significant association between suture type and the incidence of PVLs [9, 10]. Although the nonpledget suture technique has been recognized for its safe design in reducing PPM, current literature on its clinical unitility has remained divided. Additionally, a paucity of studies have investigated outcomes with the figure-of-eight technique despite its potential to reduce PPM in small-valve AVR [8, 13]. We report a retrospective, single-center study to assess PPM in patients undergoing AVR with the pledget or the figure-of-eight suture technique. The findings of this study will contribute to understanding the choice of surgical suture techniques during AVR and elucidate ways to improve outcomes in patients requiring AVR.

Methods

Patient selection

From January 2011 to July 2018, 676 patients underwent a surgical AVR using either the pledgeted or figure-of-eight suture technique at The University of Chicago Medical Center. Of the original 676 patients, 629 (93%) met the requisite inclusion criteria. Patients who received a TAVR were excluded. Patients for whom a suture technique other than the pledgeted or figure-of-eight suture was used were excluded. There were three aortic valves for which manufacturer EOA was unavailable: the Edwards Magna sizes 27 and 29, and the St. Jude Trifecta size 19. Patients with unknown implanted valve size, valve manufacturer, manufacturer EOA, preoperative height or preoperative weight were excluded. This study was approved by the Institutional Review Board of The University of Chicago (IRB20-0360) on March 27, 2020. Individual patient consent was waived as the study design is retrospective and there was no interference with patient treatment.

Surgical technique

All patients underwent a standard AVR procedure through a complete median sternotomy. The existing aortic valve was de-calcified, and all debris was meticulously removed. In the pledgeted suture technique, 9 to 20 pledgeted mattress 2-0 Ti-Cronā„¢ sutures (Ti-Cronā„¢; Medtronic, Minnesota, USA) were placed around the circumference of the ventricular side of the annulus in a horizontal mattress fashion. Using two needles, all sutures were passed from the ventricular side of the annulus to the aortic side of the annulus and through the prosthetic valve sewing ring. In the figure-of-eight suture technique, 12 to 30 figure of eight 2-0 Ti-Cronā„¢ sutures were used to secure the new aortic valve. One needle was repeatedly passed from the ventricular side of the annulus to the aortic side of the annulus and through the prosthetic valve sewing ring. The other needle remained on the ventricular side of the annulus, achieving semi-intraannular positioning. Both the figure-of-eight and pledget techniques are well visualized in Fig.Ā 1 of the report written by Kim and colleagues [10]. Employing pledgets increases the distance between sutures; therefore, more figure-of-eight sutures could be placed in comparison to the pledget suture technique. All prosthetic valves were properly seated without difficulty.

Fig. 1
figure 1

Rate of PPM across AVR suture techniques in the overall patient population. The rates of moderate PPM and no PPM were significantly different between the figure-of-eight and pledget suture technique. Moderate, pā€‰=ā€‰0.022; Severe, pā€‰=ā€‰0.59. PPM prosthesis-patient mismatch; AVR aortic valve replacement

Data collection

Using the Cardio Valve application (Ā© 2012 Digital Medical Networks), valve EOA was determined. The Cardio Valve application utilizes an algorithm derived from existing aortic prosthetic valve literature and valve manufacturer information to estimate EOA for a given valve type and size. Indexed effective orifice area (iEOA) was calculated by dividing the EOA from the Cardio Valve application by the preoperative patient body surface area (BSA). PPM was defined according to the iEOA value. PPM for an iEOA greater than 0.85 cm2/m2 was defined as ā€œnoneā€, for an iEOA between 0.65 and 0.85 cm2/m2 was defined as ā€œmoderateā€, and for an iEOA of less than 0.65 cm2/m2 was defined as ā€œsevereā€. Incidence of PPM was compared across AVR suture techniques (pledgeted suture technique, figure-of-eight suture technique), valve types (bioprosthetic, mechanical), valve sizes (sizes 19, 21, 23, 25, 27, 29), and valve manufacturers (ATS APexā„¢, Edwards PERIMOUNTā„¢, Edwards Magnaā„¢, MCRI On-Xā„¢, Medtronic 3Fā„¢, Medtronic Mosaicā„¢, St. Jude Trifectaā„¢).

Statistical analysis

For the statistical analysis, two-sided p values ofā€‰<ā€‰0.05 were considered statistically significant. Continuous data is reported as mean and standard deviation if normally distributed, or median and interquartile range (IQR) if skewed. Continuous variables were compared using Mannā€“Whitney U test. Categorical variables are expressed as number and percentage of patients and were compared using Fisherā€™s exact test.

Results

A total of 629 patients were studied for incidence of moderate and severe PPM. Among suture techniques, 570 patients (90.6%) underwent AVR with pledget sutures and fifty-nine patients (9.4%) underwent AVR with figure-of-eight sutures (Table 1). Eighty-one patients had undergone a prior aortic valve procedure; of these, five patients (6.2%) had undergone a prior aortic valve repair, forty-five (55.6%) had undergone a prior aortic valve replacement, and thirteen (16%) had undergone a prior aortic valvuloplasty. Among valve types, 534 patients (84.9%) received a bioprosthetic valve and 95 patients (15.1%) received a mechanical valve. Among valve manufacturers, 103 patients (16.4%) received an Edwards Magnaā„¢ valve, 11 patients (1.7%) received an Edwards PERIMOUNTā„¢ valve, 94 patients (14.9%) received an MCRI On-Xā„¢ valve, 415 patients (66.0%) received a St. Jude Trifectaā„¢ valve, and 6 patients (1.0%) received another type of valve (ATS Apexā„¢, Medtronic 3Fā„¢, Medtronic Mosaicā„¢).

Table 1 Demographic and baseline characteristics between pledgeted suture technique and figure-of-eight suture technique, and p-values

Demographic characteristics, medical history and other pre-, peri-, and post-operative patient data were compared between the pledgeted and figure-of-eight patients (Table 1). There was no significant difference between groups in terms of sex, history of diabetes mellitus, preoperative hemodialysis, or past aortic valve surgery. The body surface area measurements of the figure-of-eight group was significantly higher than the pledget group (pā€‰=ā€‰0.008). Additionally, there was no significant difference between groups in baseline measurements of aortic valve stenosis. Patients who received a figure-of-eight suture were more likely to be former or current smokers and were more likely to have severe aortic valve insufficiency at baseline. Figure-of-eight suture patients also had a higher average baseline ejection fraction. Patients who received a pledgeted suture were more likely to be older, had a higher average baseline creatinine level, spent more time on cardiopulmonary bypass, and had a longer average hospital length of stay, both total and postoperatively.

Patients who received the figure-of-eight suture exhibited significantly lower rates of moderate PPM compared to patients who received pledget sutured (Fig.Ā 1; pā€‰=ā€‰0.022). The pledget suture technique further remained independently associated with moderate PPM when adjusting for valve type and manufacturer: OR 2.65 (CI 1.35ā€“4.70, pā€‰=ā€‰0.007). Of the 570 pledgeted suture patients, 167 exhibited moderate PPM (29.3%), compared to 9 out of 59 figure-of-eight suture patients (15.3%). Patients who received the figure-of-eight suture also more commonly had no PPM (pā€‰=ā€‰0.044). Of the 570 pledgeted suture patients, 394 demonstrated no PPM (69.2%), compared to 49 out of 59 figure-of-eight suture patients (83.1%).

The association between suture technique and PPM was further compared between small (19ā€“23Ā mm) and large (25ā€“29Ā mm) valve sizes (Table 2). In the small valve cohort, the rate of moderate PPM in patients who received the pledgeted suture was higher than that of the figure-of-eight technique. However, this result was not statistically significant due to a limited sample size of small-valve patients (pā€‰=ā€‰0.14). In patients who were implanted with larger valves, there was neither a statistically significant nor a practically significant difference in PPM among suture techniques.

Table 2 Rate of PPM across AVR suture techniques and aortic valve sizes.

Discussion

Patients undergoing the figure-of-eight suture technique had a significantly lower rate of moderate PPM in comparison to the pledgeted cohort (Fig.Ā 1). Tabata and colleagues achieved similar results and found their pledgeted cohort to have a higher incidence of PPM than their nonpledgeted group [9]. Unlike our methodology, however, they employed a simple interrupted suture as their nonpledgeted technique. To our knowledge, Kim et al. have written the only other report to compare PPM outcomes in patients receiving the pledget and figure-of-eight suture [10]. Notably, they study a sample with an East Asian demographic, whereas we study Western patients who generally require larger replacement valves and have different hemodynamic outcomes compared to their Eastern counterparts [11, 12]. Additionally, they focus on comparing suture techniques employed in a small aortic annulus. We assess patients with both a small and large aortic annulus. They report that both the pledget suture technique and figure-of-eight suture technique were associated with moderate PPM. However, they combined their pledget and figure-of-eight cohorts into one sample for univariate and multivariate analysis. As a result, their pledget and nonpledget techniques were assessed together as a single risk factor for PPM incidence. Ugar and associates conducted a one-year retrospective analysis, investigating hemodynamic data in particularly Western patients [11]. They did not vary suture technique in their pledgeted cohort, and likewise, found no association between the noneverting pledget-reinforced suture and the incidence of severe PPM. In contrast with our study, however, they compared these pledget outcomes with the everting mattress suture technique.

Most recently, Saisho and colleagues investigated suture technique in AVR with an ex vivo model and achieved a significantly larger EOA with the figure-of-eight technique compared to the pledget technique [13]. Their model included a porcine aortic root, the PERIMOUNT Magna Ease 21Ā mm valve, and a mock circulation loop that simulated physiologic flow and captured EOA and leakage volume. The larger EOA from the figure-of-eight technique was credited to its intra-annular valve positioning and orientation of its sutures, which is consistent with our findings. Since one suture enters from the supra-annular end and the other passes through the ventricular side, the tissue can be ultimately pulled outwards from the valve orifice. In contrast, the pledget technique grants supra-annular valve positioning and its suture orientation can cause tissue to protrude through the left ventricular outflow tract and obstruct flow.

We utilized Fischerā€™s exact test to compare the rates of moderate PPM by procedure type (pledget vs figure-of-eight). Dividing the patients into those with smaller and larger valve sizes reduced the sample size, lowering statistical power. However, a significant difference in moderate PPM was observed when the valve size groups were combined, likely due to the larger sample size and greater power. The small valve size group in particular did not reach statistical significance despite a large numerical difference in the proportion of patients with moderate PPM, possibly due to the small amount of figure-of-eight patients. Consideration of Simpsonā€™s paradox due to the larger fraction of figure-of-eight patients who were of large valve size, which possessed a lower rate of PPM, are important, but cannot be resolved given the sample size limitations of the present study.

We chose to evaluate PPM, as it is a well-known, modifiable predictor of post-operative hemodynamic abnormalities and all-cause mortality [14,15,16,17,18,19,20,21,22,23,24]. This may be due to the high-pressure gradients caused by PPM, which can lead to left-ventricular hypertrophy and ultimately result in left ventricular failure. In a systematic review and meta-analysis of 34 observational studies, Head et al. found moderate and severe PPM to significantly predict all-cause mortality and cardiac-related mortality [22]. Tasca and colleagues reached similar findings between PPM and cardiac-related mortality, and further characterized PPM as a predictor of mid-term mortality [23]. However, there remain several studies that report a small impact of PPM on mortality and adverse hemodynamic outcomes [24,25,26]. These studies define PPM as a product of the internal geometric orifice area (GOA) rather than the EOA of the prosthesis. Although this measurement is more reproducible than the EOA, utilizing the GOA has been shown to be a poor predictor of transvalvular pressure gradients following AVR [24, 27]. Thus, these studies cannot be drawn upon to create an accurate relationship between PPM and post-operative mortality or sequalae.

In addition to PPM, several other complications can occur following AVR and increase mortality risk, including infectious endocarditis, chronic lung disease, and reduced left ventricular ejection fraction [8]. Factors such as age, gender, and coronary artery disease can further compound this risk; however, these complications and factors cannot be readily prevented or manipulated. Although this information may offer some insight regarding AVR risk for patients, it cannot be used to develop a strategy for reducing AVR mortality risk. In this present study, we assert that suture design can be modified by surgeons to limit PPM; particularly, the nonpledgeted figure-of-eight suture method can be used as a prospective strategy for reducing post-AVR mortality risk and hemodynamic abnormalities in patients with small valve sizes.

TAVR has gained traction as a beneficial, minimally invasive procedure in patients who are deemed inoperable or who are opposed to surgical AVR. According to Puri et. al., TAVR grants equivalent clinical outcomes to surgical aortic valve replacement and maintains clinical superiority in patients with severe aortic stenosis [28]. However, the degree of benefit following TAVR depends heavily on trans-aortic pressure gradients, and for a large number of patients with low-pressure gradients, TAVR has minimal functional benefit post-operatively [29,30,31]. In a cohort undergoing TAVR for severe aortic stenosis, Yadav and colleagues report that each 10Ā mmHg decrease in transaortic pressure gradients results in a 20% increase in mortality [29]. PPM is a measure of iEOA and has a strong association with low transaortic pressure gradients. Considering the figure-of-eight suture technique yields low rates of moderate-to-no PPM, this method may also minimize adverse outcomes for patients undergoing TAVR who have critical aortic stenosis. The figure-of-eight technique can further reduce the incidence of annular rigidity and calcification, adding to its reliability in TAVR procedures.

Regarding the limitations of our study, a relatively small cohort of patients at our center underwent AVR utilizing a figure-of-eight suture. This was due to the restricted, retrospective nature of our study and the general low incidence of figure-of-eight sutures utilized in AVR procedures. As a result, we did not divide our sample into smaller cohorts based on valve type and manufacturer; however, we employed logistic regression to confirm that these variables were not confounders. The pledget suture technique remained independently associated with moderate PPM after adjusting for valve type and manufacturer. Regarding suture technique, there was variability in the number of pledgeted sutures employed by each surgeon, and a lower number of pledget sutures may narrow the aortic root and result in PVLs. However, the majority of patients in the pledget cohort received 12ā€“15 sutures (71.2%), whereas 18 patients received 9ā€“11 sutures (3.2%) and 36 patients received 16ā€“23 sutures (6.3%). Other surgeons did not comment on the number of pledgeted sutures utilized during their AVR operations (19.3%). We were unable to control for this variability due to the retrospective design of our study and differences in surgeon preference; however, a small subset (3.2%) of our patient population received below 12 pledget sutures, which could have caused a narrowing of the aortic root. We further did not associate suture technique with direct clinical outcomes such as paravalvular leaks and ejection fraction, as these comparisons have already been conducted in past literature [3, 12]. PPM is also a strong predictor of mortality and hemodynamic outcomes, so we can imply from our findings that suture type has an indirect yet significant influence on these clinical measures. Another limitation is our use of the cardiovalve application to estimate EOA values. This was necessited by the usage of past echocardiograms which did not include EOA measurements. As a result, we could not directly assess EOA in our patients, and instead utilized a reliable application to conduct indirect estimates.

Conclusion

Suture technique can have a significant impact on PPM and its post-operative outcomes following AVR. Physicians operating AVR have mainly limited their approach to the simple interrupted suture technique or the interrupted suture with unabsorbable pledgets. We study a far-less utilized method, the figure-of-eight suture, and present it for the first time as a solution that can reduce moderate PPM following AVR. We also report that the figure-of-eight suture can yield significant rates of no PPM and offset adverse hemodynamic outcomes. Although the pledget suture has long been considered the standard technique in AVR, the figure-of-eight suture method may grant superior structural and hemodynamic results, especially in patients with a small aortic annulus who are at greater risk for such mismatch.

Availability of data and materials

The dataset supporting the conclusions of this article is available in the University of Chicago electric medical record repository.

Abbreviations

AVR:

Aortic valve replacement

PVL:

Paravalvular leak

EOA:

Effective orifice area

iEOA:

Indexed effective orifice area

TAVR:

Transcatheter valve replacement

PPM:

Prosthesis-patient mismatch

BSA:

Body surface area

IQR:

Interquartile range

GOA:

Geometric orifice area

References

  1. Ye J, Soon J, Webb J. Aortic valve replacement vs. transcatheter aortic valve implantation: patient selection. Ann Cardiothorac Surg. 2012;1:194ā€“9.

    PubMedĀ  PubMed CentralĀ  Google ScholarĀ 

  2. Chan PG, Chan EG, Seese L, et al. Safety and feasibility of a nonpledgeted suture technique for heart valve replacement. JAMA Surg. 2019;154:260ā€“1.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  3. Englberger L, Schaff H, Jamieson W, Kennard E, Im K, Holubkov R, et al. Importance of implant technique on risk of major paravalvular leak (PVL) after St. Jude mechanical heart valve replacement: a report from the Artificial Valve Endocarditis Reduction Trial (AVERT). Eur J Cardio Thorac Surg. 2005;28:838ā€“43.

    ArticleĀ  Google ScholarĀ 

  4. Rallidis L, Moyssakis I, Ikonomidis I, Nihoyannopoulos P. Natural history of early aortic paraprosthetic regurgitation: a five-year follow-up. Am Heart J. 1999;138:351ā€“7.

    ArticleĀ  CASĀ  PubMedĀ  Google ScholarĀ 

  5. Tamburino C, Capodanno D, Ramondo A, Petronio A, Ettori F, Santoro G, et al. Incidence and predictors of early and late mortality after transcatheter aortic valve implantation in 663 patients with severe aortic stenosis. Circulation. 2011;123:299ā€“308.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  6. Kodali S, Pibarot P, Douglas P, Williams M, Xu K, Thourani V, et al. Paravalvular regurgitation after transcatheter aortic valve replacement with the Edwards sapien valve in the PARTNER trial: characterizing patients and impact on outcomes. Eur Heart J. 2014;36:449ā€“56.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  7. Tabata M, Shibayama K, Watanabe H, Sato Y, Fukui T, Takanashi S. Simple interrupted suturing increases valve performance after aortic valve replacement with a small supra-annular bioprosthesis. J Thorac Cardiovasc Surg. 2014;147:321ā€“5.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  8. Kim H, Lee S, Joo H, Kim J, Youn Y, Yoo K, et al. Impact of suture techniques for aortic valve replacement on prosthesis-patient mismatch. Ann Thorac Surg. 2020;109:661ā€“7.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  9. Ugur M, Byrne J, Bavaria J, Cheung A, Petracek M, Groh M, et al. Suture technique does not affect hemodynamic performance of the small supra-annular Trifecta bioprosthesis. J Thorac Cardiovasc Surg. 2014;148:1347ā€“51.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  10. LaPar D, Ailawadi G, Bhamidipati C, Singh M, Dare D, Kern J, et al. Use of a nonpledgeted suture technique is safe and efficient for aortic valve replacement. J Thorac Cardiovasc Surg. 2011;141:388ā€“93.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  11. Sakamoto Y, Hashimoto K. Update on aortic valve prosthesis-patient mismatch in Japan. Gen Thorac Cardiovasc Surg. 2013;61:669ā€“75.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  12. Tadokoro N, Fukushima S, Shimahara Y, Matsumoto Y, Yamashita K, Kawamoto N, et al. Trifecta vs. magna for aortic valve replacementā€”differences in clinical outcome and valve hemodynamicsā€”. Circ J. 2018;82:2767ā€“75.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  13. Saisho H, Kuhlmann C, Scharfschwerdt M, Jeganathan R, Sadat N, Schaller T, et al. The figure-of-8 aortic valve suturing technique optimizes the ef- fective orifice area of a small aortic annulusā€”an ex vivo study. Eur J Cardiothorac Surg. 2022. https://doi.org/10.1093/ejcts/ezac195.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  14. Blais C, Dumesnil J, Baillot R, Simard S, Doyle D, Pibarot P. Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replacement. Circulation. 2003;108:983ā€“8.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  15. Ruel M, Rubens F, Masters R, Pipe A, BĆ©dard P, Hendry P, et al. Late incidence and predictors of persistent or recurrent heart failure in patients with aortic prosthetic valves. J Thorac Cardiovasc Surg. 2004;127:149ā€“59.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  16. Walther T, Rastan A, Falk V, Lehmann S, Garbade J, Funkat A, et al. Patient prosthesis mismatch affects short- and long-term outcomes after aortic valve replacement. Eur J Cardiothorac Surg. 2006;30:15ā€“9.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  17. Mohty-Echahidi D, Malouf J, Girard S, Schaff H, Grill D, Enriquez-Sarano M, et al. Impact of prosthesis-patient mismatch on long-term survival in patients with small St Jude Medical mechanical prostheses in the aortic position. Circulation. 2006;113:420ā€“6.

    ArticleĀ  Google ScholarĀ 

  18. Dumesnil J, Honos G, Lemieux M, Beauchemin J. Validation of applications of indexed aortic prosthetic valve areas calculated by Doppler echocardiography. J Am Coll Cardiol. 1990;16:637ā€“43.

    ArticleĀ  CASĀ  PubMedĀ  Google ScholarĀ 

  19. Pibarot P, Dumesnil J. Hemodynamic and clinical impact of prosthesisā€“patient mismatch in the aortic valve position and its prevention. J Am Coll Cardiol. 2000;36:1131ā€“41.

    ArticleĀ  CASĀ  PubMedĀ  Google ScholarĀ 

  20. Rao V, Jamieson WRE, Ivanov J, Armstrong S, David TE. Prosthesis-patient mismatch affects survival following aortic valve replacement. Circulation. 2000;102:5ā€“9.

    ArticleĀ  Google ScholarĀ 

  21. Pibarot P, Dumesnil J, Cartier P, MĆ©tras J, Lemieux M. Patient-prosthesis mismatch can be predicted at the time of operation. Ann Thorac Surg. 2001;7:265ā€“8.

    ArticleĀ  Google ScholarĀ 

  22. Head S, Mokhles M, Osnabrugge R, Pibarot P, Mack M, Takkenberg J, et al. The impact of prosthesisā€“patient mismatch on long-term survival after aortic valve replacement: a systematic review and meta-analysis of 34 observational studies comprising 27 186 patients with 133 141 patient-years. Eur Heart J. 2012;33:1518ā€“29.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  23. Tasca G, Mhagna Z, Perotti S, Centurini PB, Sabatini T, Amaducci A, et al. Impact of prosthesis-patient mismatch on cardiac events and midterm mortality after aortic valve replacement in patients with pure aortic stenosis. Circulation. 2006;113:570ā€“6.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  24. Fernandez J, Chen C, Laub GW, Anderson WA, Brdlik OB, Murphy MS, et al. Predictive value of prosthetic valve area index for early and late clinical results after valve replacement with the St Jude Medical valve prosthesis. Circulation. 1996;94:109ā€“12.

    Google ScholarĀ 

  25. Medalion B, Blackstone E, Lytle B, White J, Arnold J, Cosgrove D. Aortic valve replacement: Is valve size important? J Thorac Cardiovasc Surg. 2000;119:963ā€“74.

    ArticleĀ  CASĀ  PubMedĀ  Google ScholarĀ 

  26. Blackstone E, Cosgrove D, Jamieson W, Birkmeyer N, Lemmer J, Miller D, et al. Prosthesis size and long-term survival after aortic valve replacement. J Thorac Cardiovasc Surg. 2003;126:783ā€“93.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  27. Koch CG, Khandwala F, Estafanous FG, Loop FD, Blackstone EH. Impact of prosthesis-patient size on functional recovery after aortic valve replacement. Circulation. 2005;111:3221ā€“9.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  28. Puri R, Iung B, Cohen D, RodĆ©s-Cabau J. TAVI or No TAVI: identifying patients unlikely to benefit from transcatheter aortic valve implantation. Eur Heart J. 2016;37:2217ā€“25.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  29. Yadav P, Eng M. Power of gradients. Catheter Cardiovasc Interv. 2017;90:1183ā€“4.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  30. Levy F, Laurent M, Monin J, Maillet J, Pasquet A, Le Tourneau T, et al. Aortic valve replacement for low-flow/low-gradient aortic stenosis. J Am Coll Cardiol. 2018;51:1466ā€“72.

    ArticleĀ  Google ScholarĀ 

  31. Nishimura RA, Grantham JA, Connolly HM, Schaff HV, Higano ST, Holmes DR, et al. Low-output, low-gradient aortic stenosis in patients with depressed left ventricular systolic function: the clinical utility of the dobutamine challenge in the catheterization laboratory. Circulation. 2002;106:809ā€“13.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

Download references

Acknowledgements

None declared.

Funding

As this is retrospective chart review, there was no funding support, and this research was not performed as part of the employment of the authors.

Author information

Authors and Affiliations

Authors

Contributions

NR: Writingā€”original draft; Writingā€”review; Formal analysis; Investigation; Conceptualization. CS: Writingā€”original draft; Supervision; Data collection; Formal analysis. Conceptualization. ZL Writingā€”original draft; Formal analysis; Supervision; Data collection. US: Writingā€”original draft; Formal analysis; Data collection. ACHL: Data collection; Formal analysis; Investigation. WL: Data collection; Formal analysis; Investigation. SL: Data collection; Formal analysis; Investigation. JC: Data collection; Formal analysis; Investigation. WGC: Writingā€”feedback and editing. CS: Data curation; Queried data for analysis. DR: Supervision; Methodology; Investigation. MM: Supervison; Methodology; Investigation. PC: Project administration; Supervision; Writingā€”editing. VJ: Conceptualization; Project administration; Supervision. NH: Conceptualization; Project administration; Supervision; Visualization; Investigation; Methodology; Writingā€”feedback and editing. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Nabeel F. Rasheed.

Ethics declarations

Ethics approval and consent to participate

IRB20-0360 approved on 3/27/2020.

Consent for publication

Not applicable.

Competing Interests

The authors declare that they have no competing interests.

Informed consent

None declared.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Rasheed, N.F., Stonebraker, C., Li, Z. et al. Figure of eight suture technique in aortic valve replacement decreases prosthesis-patient mismatch. J Cardiothorac Surg 18, 117 (2023). https://doi.org/10.1186/s13019-023-02260-y

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13019-023-02260-y